How electricity works in New Zealand.
New Zealand electricity market 2026: Electricity Authority, Transpower, 29 lines companies, the ICP and Registry, smart meters, solar export, licensing and reforms.
This overview covers what electricity costs, how much a typical household uses, how the grid is run and regulated, and whether homes can send electricity back to the grid. Figures are shown in New Zealand dollar (NZD) where they relate to prices.
Each important figure links to its public source and states the year it refers to. Where no reliable public figure was found, the page says so. Unfamiliar terms are explained in our glossary.
New Zealand energy at a glance.
Key figures for households in New Zealand. Each one links to its source on the full overview below.
Electricity price.
0.421 NZD per kWh for households, including taxes. Figures for 15 August 2026.
Household use.
7,048 kWh a year for a typical household. Figures for Year to March 2025.
Renewable share.
88.5% of electricity from renewable sources. Figures for 2025.
Selling back to the grid.
Can homes export electricity? Yes. Details are in the export section below.
Four things to check in New Zealand.
Rules and schemes change. Use this page as a starting point, then confirm the details that matter to you.
Check the local rules.
Read the connection, export and permission rules for New Zealand below, and ask your local grid operator if anything is unclear.
Choose a qualified installer.
Look for an installer listed on an official register, with the certifications New Zealand requires for the work.
Look at current schemes.
Check which support schemes are open now. Closed or scheduled schemes are labelled as such.
Talk to your energy supplier.
Ask how new equipment, such as solar or a battery, could affect your tariff and any export payments.
Schemes, rules and certifications in New Zealand.
The full detail sits in the sections below. Each item shows its status and links to the official source.
Support schemes.
Grants, tax relief and export payments in New Zealand, each labelled Active, Scheduled or Closed.
Connection and export.
How equipment is connected to the grid in New Zealand, and the steps to export electricity.
Standards and certifications.
The technical standards and installer certifications that apply to energy equipment in New Zealand.
The energy market in New Zealand, in detail.
Each figure shows the year it refers to and a numbered link to its public source, listed at the end of the page.
Profile last updated 1 October 2026.
On this page22 sections
New Zealand runs a single, isolated national grid with no links to other countries. Transpower, a state-owned enterprise, owns the high-voltage grid and acts as system operator, and 29 electricity distribution businesses (“lines companies”) own the local networks. The Electricity Authority writes and enforces the Electricity Industry Participation Code, which governs the wholesale market, retail switching, metering and the connection of distributed generation, while the Commerce Commission regulates what Transpower and the lines companies can charge.
The power system is unusually renewable. In 2025, 88.5% of the 44,140 GWh generated came from renewable sources, mainly hydro (about 55%) and geothermal (about 22%), the highest renewable share since 1981. The market is fully competitive at retail level, but four large “gentailers” that own both generation and retail businesses (Mercury, Genesis, Contact and Meridian) supply about four in five connections. There is no regulated price cap: the government’s Quarterly Survey of Domestic Electricity Prices put the average advertised household price at 42.1 cents per kWh including GST in August 2026.
Every connection point is identified by a 15-character ICP identifier held in the national Registry. Smart meters are almost universal: about 96% of residential connections had one at the end of August 2026, installed through a market-led rollout rather than a government mandate. Households can export rooftop solar under a regulated connection process in Part 6 of the Code, and since 1 April 2026 lines companies must pay a rebate to small consumers who export at peak times.
Energy snapshot.
Headline figures for electricity in New Zealand. Each shows its data year and links to its source.
- Population5,357,300 peopleSource 230 June 2026 (provisional)
- Households1,780,527 householdsSource 32023 Census
- Average household size2.7 people/householdSource 42023 Census
- Electricity use per household7,048 kWh/yrSource 7Year to March 2025
- Household price (NZD)0.421 NZD/kWhSource 815 August 2026
- Household price (EUR)0.209 EUR/kWhSource 1115 August 2026
- Renewable electricity share88.5%Source 122025
- Solar capacity0.83 GWSource 12end 2025
- Wind capacity1.265 GWSource 14December 2025
- Energy storage capacity0.235 GWSource 15May 2026
- Smart-meter share96.1%Source 1631 August 2026
- Market structure
- Fully liberalised
- Homes can export to the grid
- Yes
- Home equipment in grid services
- Restricted
- Regulator
- Electricity Authority (market rules and Code); Commerce Commission (network price-quality regulation)
- System operator
- Transpower New Zealand (grid owner and system operator)
- Distribution networks
- 29 electricity distribution businesses (lines companies), owned by private investors, councils and consumer trusts
- Currency
- New Zealand dollar (NZD)
- Voltage and frequency
- 230 V / 50 Hz
Electricity prices in New Zealand.
- Household price (NZD)
- 0.421 NZD/kWh (15 August 2026)Source 8National average of advertised low-user plans for a modelled household using 8,000 kWh a year, including GST, fixed charges and prompt-payment discounts. Lines charges make up 16.8c and energy and other costs 25.3c. Prices range from 37.2c in Wellington to 51.0c in Balclutha.
- Household price (EUR)
- 0.209 EUR/kWh (15 August 2026)Source 11Converted from NZ$0.421/kWh at the ECB reference rate of 30 September 2026 (EUR 1 = NZD 2.0115).
- Typical annual electricity bill
- 3,368 NZD/yr (15 August 2026)Source 8Derived: 8,000 kWh × the QSDEP national average of 42.1c/kWh. This is a modelled advertised price, not what households actually paid; at the MBIE average use of 7,048 kWh the same price gives about NZ$2,970.
Household price trend (NZD per kWh).Source 8
| Aug 2021 | 0.312 NZD/kWh |
|---|---|
| Aug 2022 | 0.325 NZD/kWh |
| Aug 2026 | 0.421 NZD/kWh |
What makes up the price
MBIE splits the average advertised price into a lines component (transmission and distribution charges, 16.8c/kWh in August 2026) and an “energy and other costs” component (wholesale energy, metering, retail costs and margin, 25.3c/kWh). Goods and services tax of 15% is included in all household prices. Lines companies set their own tariffs within the revenue limits set by the Commerce Commission, and retailers pass them through; only one network, The Lines Company, bills residential consumers directly.
No price cap
Unlike in Great Britain or Australia, New Zealand has no default tariff or price cap. Retailers set their own prices, and consumers compare plans on Consumer NZ’s Powerswitch site. Competition rules focus instead on the wholesale and hedge markets: from 1 July 2026 the four gentailers must supply hedge contracts on non-discriminatory terms to independent retailers.
Regional differences
Prices vary widely between lines company areas because network costs are spread over different numbers of customers. In August 2026 the average ranged from 37.2c/kWh in Wellington and 38.2c in Ashburton to 50.6c in Kerikeri and 51.0c in Balclutha. Many consumer-trust-owned lines companies also pay annual dividends or discounts to their customers, which are not included in the survey prices.
Rising network charges
Lines charges have risen since 1 April 2025, when the Commerce Commission’s fourth default price-quality path (DPP4) for 2025–2030 allowed much higher revenue to fund network investment. The national average advertised price rose from 31.2c/kWh in August 2021 and 32.5c in August 2022 to 42.1c in August 2026. Low users are also affected by the phase-out of the Low Fixed Charge regulations, which lets retailers raise daily charges each April until the regulations end in April 2027.
Tariff types.
| Tariff | Available | Detail |
|---|---|---|
| Variable | Yes | Most households are on open-term plans with a daily fixed charge plus a price per kWh, which retailers can change with notice. Prices are not capped by any regulator. |
| Fixed | Yes | Many retailers offer fixed-term contracts that hold the rates for one to three years, usually with a break fee. |
| Time-of-use | Yes | Peak/off-peak and day/night plans use smart meter data. Under Electricity Authority rules, retailers with more than 5% market share had to offer time-varying pricing plans by 30 June 2026, with additional obligations from 1 October 2026 for any that do not meet the requirement. |
| Dynamic | Limited | Plans that pass through the half-hourly wholesale spot price have been offered in the past, notably by Flick Electric, which became part of Meridian in July 2025. Such plans are now uncommon. |
| Off-peak | Yes | Controlled hot-water tariffs are widespread: the hot-water cylinder is metered on a separate register and can be switched off by the lines company’s ripple control at peak times in exchange for a lower rate. MBIE’s model household assumes ripple-controlled water heating. |
| Regulated | Limited | There is no regulated price cap. Retailers have had to offer a low fixed charge option to low users under the Low Fixed Charge regulations, which are being phased out: the maximum daily charge rises in steps and the regulations end on 1 April 2027. |
| Prepayment | Yes | Prepay electricity is offered by a small number of retailers, such as Wise Prepay Energy, using smart meters. |
Household prices compared with neighbouring countries (EUR per kWh).
- Australia€0.244
- New Zealand€0.209
Household prices including taxes, converted to euros as stated on each country page.
Household electricity use.
- Electricity use per household
- 7,048 kWh/yr (Year to March 2025)Source 7MBIE sales-based average residential consumption per household (7,088 kWh in the year to March 2024). The QSDEP price survey uses a higher modelled household of 8,000 kWh a year.
- Average daily use per household
- 19.3 kWh/day (Year to March 2025)Source 7Derived: 7,048 kWh a year divided by 365.
- Typical household peak demand
- Not identified from a reliable public source.
- Electricity use per person
- 7,989 kWh/person/yr (all sectors) (2024)Source 46Electric power consumption per capita across all sectors. Residential use was 50.09 PJ (about 13.9 TWh) in 2025, about a third of national consumption (MBIE).
- Heat pumps
- 66.8 % of dwellings (main heating) (2023 Census)Source 37Share of dwellings using a heat pump as a main type of heating, up from 47.3% in 2018. Wood burners were a main heating type in 28.2% of dwellings.
- Air conditioning
- Not identified from a reliable public source.
- Electric vehicles
- 92,628 battery electric vehicles (end 2025)Source 12Ministry of Transport fleet statistics cited by MBIE; up from 83,902 a year earlier, and 1.9% of the vehicle fleet. Including plug-in hybrids there were 113,715 EVs at the end of 2024 (EHINZ).
- Electric cooking
- Not identified from a reliable public source.
Electricity does much of the heating work in New Zealand homes. MBIE’s model household heats its water electrically in a ripple-controlled cylinder, and heat pumps have become a main heating appliance in two-thirds of homes, while the use of wood burners and portable gas heaters has fallen. Demand peaks on cold winter mornings and evenings: residential consumption reached a quarterly record of 4,509 GWh in the September 2025 quarter, and national grid demand set a record of 7,415 MW in August 2026.
Annual residential consumption has been broadly flat at about 7,000 kWh per household for several years, and fell 1.4% in 2025 as efficiency and rooftop solar offset growth in electric heating. Electricity used for transport rose 18% in 2025 to 394 GWh as the battery electric fleet grew to 92,628 vehicles, still only 1.9% of all vehicles.
Housing and households.
- Dwellings
- Not identified from a reliable public source.
- Owner-occupied
- 66% (2023 Census)Source 3Home ownership rate including dwellings held in a family trust (978,105 owner-occupied plus 197,112 trust-held households), up from 64.5% in 2018.
- Private rented
- 28.7 % of households (2023 Census)Source 5Derived: 604,884 renting households (34.0% of households) × 84.6% renting from a private person, trust or business.
- Social or public housing
- 4.9 % of households (2023 Census)Source 5Derived: 34.0% renting × 14.4% renting from Kāinga Ora (11.2%), a council (1.7%) or another community housing provider (1.5%).
- Houses
- 77.5 % of occupied dwellings (2023 Census)Source 6Separate houses: 57.1% one-storey and 20.4% two or more storeys.
- Apartments and flats
- Not identified from a reliable public source.
- Urban population
- 84 % of population (2025)Source 44
Most New Zealanders live in detached houses, more than half of them single-storey, which gives many homes a roof suitable for solar panels. Joined dwellings such as townhouses and low-rise flats make up most of the rest; high-rise apartments are concentrated in central Auckland and Wellington.
Two-thirds of households own their home (including through a family trust) and about a third rent, mostly from private landlords. Renters face the usual barriers to installing solar or batteries. Building consents are no longer needed for most roof-mounted solar arrays up to 40 m² since October 2025, but body corporates and landlords still control what can be installed on shared or rented buildings.
How the grid works in New Zealand.
- TransmissionTranspower New Zealand
- Distribution29 electricity distribution businesses (lines companies), owned by private investors, councils and consumer trusts
- MeteringMetering equipment providers (MEPs), The Registry (operated by Jade Software for the Electricity Authority)
- Supply8 or more retail suppliers
Physical flow
Large hydro stations in the South Island and on the Waikato River, geothermal plants in the Taupō Volcanic Zone and wind farms mostly in the North Island feed Transpower’s national grid. The HVDC link carries South Island hydro power north to the main demand centres in Auckland, Waikato and Wellington. Electricity leaves the grid at grid exit points (GXPs), where the 29 lines companies take it through their local networks to homes and businesses. The Tiwai Point aluminium smelter in Southland is the largest single user.
Commercial flow
Generators offer into a nodal spot market in which prices are set every half hour at points across the grid, reflecting losses and constraints. Retailers buy at the spot price for the GXPs that supply their customers and hedge with contracts, often with their own generation arm. They then sell to consumers, paying lines charges to the lines company, which in turn pays Transpower for transmission. Households deal with their retailer for billing and with the lines company for faults and solar connection approval.
Market concentration
Mercury, Genesis, Contact and Meridian (including Powershop) supplied about 84% of all ICPs at the end of August 2026. Because they own most generation, independent retailers depend on buying hedges from them. The government’s Energy Competition Task Force and the Electricity Authority responded with non-discrimination obligations on hedge supply from 1 July 2026, and legislation to strengthen the Authority’s enforcement powers is being prepared.
Who does what.
| Role | Organisation | What it does |
|---|---|---|
| Ministry | Ministry of Business, Innovation and Employment (MBIE) | Energy policy, energy statistics (including the Quarterly Survey of Domestic Electricity Prices and Energy in New Zealand), the Low Fixed Charge regulations and the Consumer Data Right. The Minister for Energy sets the government’s policy statement to the Electricity Authority. |
| Regulator | Electricity Authority (Te Mana Hiko) | Independent Crown entity that makes and enforces the Electricity Industry Participation Code: wholesale market rules, retail switching, metering, the Registry, distributed generation connection (Part 6) and consumer protections. It contracts the market operation service providers, including the registry manager, and publishes market data on its EMI website. |
| Regulator | Commerce Commission | Regulates the revenue and quality of Transpower and of lines companies under Part 4 of the Commerce Act. Fifteen lines companies are on the 2025–2030 default price-quality path (DPP4), which took effect on 1 April 2025; the remaining lines companies are not on the default path. |
| TSO | Transpower New Zealand | State-owned enterprise that owns and operates the national grid, including the HVDC link between the South and North Islands. It also acts as system operator under contract to the Electricity Authority, dispatching generation and procuring instantaneous reserves and other ancillary services. |
| DSO | Electricity distribution businesses (lines companies) | 29 lines companies own the local networks, from large investor-owned networks such as Vector (Auckland), Powerco, Wellington Electricity and Orion (Christchurch) to small consumer-trust or council-owned companies. They create ICPs for new connections, approve distributed generation under Part 6, operate ripple control of hot-water load, and set network tariffs. |
| Supplier | Retailers | Around 20 retail brands hold a measurable share of ICPs, led by the four gentailers Mercury, Genesis, Contact and Meridian (including its Powershop brand). Retailers are registered participants, buy at the wholesale spot price, pay lines charges and bill consumers. |
| Metering | Metering equipment providers (MEPs) | The trader responsible for an ICP must appoint a registered MEP. Four providers own almost all residential smart meters: Vector Metering (59%), IntelliHUB (31%), SmartCo (7%) and Counties Power (2%). |
| Data hub / registry | The Registry (operated by Jade Software for the Electricity Authority) | National database of every ICP on local and embedded networks, recording the network, trader, MEP, metering configuration, price category and status of each connection. It processes switches between retailers, MEPs and distributors. |
| Settlement | Market operation service providers | The wholesale market is settled by a clearing manager and reconciled by a reconciliation manager, both contracted by the Electricity Authority, using metering data submitted by traders against ICPs and grid exit points. |
Compared with the UK system.
| UK concept | New Zealand equivalent | How it works |
|---|---|---|
| DNO | Electricity distribution business (lines company) | Lines companies are regional monopolies like DNOs, but there are 29 of them, many owned by consumer trusts that pay dividends back to local customers. Most do not bill households directly: their charges go through the retailer. They approve rooftop solar and batteries under Part 6 of the Code and control hot-water load by ripple signal. |
| National Grid/NESO | Transpower | Transpower combines both roles: it owns the national grid (like National Grid Electricity Transmission) and is the system operator (like NESO) under contract to the Electricity Authority. The grid is a single isolated system with no international interconnectors. |
| MPAN | ICP identifier | A 15-character code for each installation control point, created by the lines company and recorded in the national Registry. It combines a 10-digit number, a two-letter code for the issuing distributor and a three-character checksum. Unlike the MPAN core it carries no profile class or meter time-switch code; the metering configuration is held in the Registry instead. |
| MPRN | Gas ICP | Gas connections also use ICP identifiers in the same 15-character structure, held on a separate gas registry under rules overseen by the Gas Industry Company. A home with both fuels has two different ICPs. |
| Meter operator | Metering equipment provider (MEP) | The retailer appoints a registered MEP for each ICP, recorded in the Registry. The MEP owns, certifies and maintains the meter and, for smart meters, collects the half-hourly data and passes it to the retailer. |
| Supplier | Retailer (“trader” in the Code) | Retailers register with the Electricity Authority as participants rather than holding a supply licence, and must belong to the Utilities Disputes scheme. There is no price cap; consumers switch through the Registry, usually within a few business days. |
| Smart-meter infrastructure | MEP-owned AMI (no DCC equivalent) | There is no central communications body. Smart meters were installed in a market-led rollout by MEPs on behalf of retailers, and each MEP runs its own communications. About 96% of residential ICPs had a smart meter in August 2026. |
How a supply point is identified.
0004827153QX4B7 (fictional; the distributor code “QX” and checksum are illustrative only)
Fictional example in the real format.
| Question | Answer |
|---|---|
| What is it called? | Installation Control Point identifier (ICP) |
| Who issues it? | The distributor (lines company) responsible for the network to which the point of connection is connected, using a distributor code assigned by the Electricity Authority |
| Format | yyyyyyyyyyxxccc: a 10-digit numerical sequence chosen by the distributor, a two-character code assigned by the Electricity Authority to the issuing distributor (which makes the ICP unique), and a three-character alphanumeric checksum generated with the Authority’s algorithm. On bills a dash may be printed before the checksum for readability, but it is not part of the identifier. |
| Length | 15 characters |
| Stays with the property when you switch supplier? | Yes |
| Where to find it | On the electricity bill (front or back depending on the retailer), labelled “ICP” or “ICP number”. It is different from the meter serial number. Retailers and the lines company can also confirm it, and the Powerswitch comparison site can usually find it from the address. |
| Electronic access | Under clauses 11.32A–11.32B of the Code, a consumer can ask their retailer (or a retailer they left in the last 24 months) for up to 24 months of their consumption and injection data at each ICP, including raw meter data. The retailer must respond within 5 business days and, since 1 June 2026, cannot charge for these requests. Data is exchanged in the Authority’s standard EIEP13 formats. |
| Third-party access | A consumer can authorise an agent, such as a comparison site, energy-management app or installer, to request their data; the retailer must grant the request unless it reasonably believes it is unauthorised. Direct Registry look-ups are restricted to registered participants. A Consumer Data Right for electricity (“Open Electricity”) is planned from mid-2027. |
| Who keeps the register | The Electricity Registry, a national database owned by the Electricity Authority and operated by Jade Software Corporation as registry manager |
| Register scope | National |
What the ICP identifies
An installation control point is the point on a local or embedded network at which a trader conveys electricity to a consumer or from an embedded generator. The ICP identifies that connection, not the customer, the retailer or the meter. It stays with the property when the occupant or retailer changes and when a meter is replaced, and it is decommissioned only when the connection is permanently removed. ICPs are also used for the connection between an embedded network (such as an apartment building or retail centre) and its parent network.
How it is created
Part 11 of the Code requires each distributor to create an ICP identifier for every ICP on its network. The first ten digits are a sequence the distributor chooses; the two letters are the code the Electricity Authority has assigned to that distributor, so two networks can never issue the same number; and the last three characters are a checksum that lets systems detect typing errors. The distributor then populates the Registry with the network-related information for the ICP, such as its network supply point and distribution price category.
Who keeps the register
The Registry is a single national database run for the Electricity Authority by its registry manager, Jade Software. For every ICP it records the distributor, the trader (retailer) responsible, the metering equipment provider, the metering configuration and the ICP’s status (for example active or inactive). Every participant must use the ICP identifier in its communications with the registry manager.
Switching and other uses
When a household changes retailer, the gaining retailer notifies the registry manager of the switch within 2 business days of agreeing to supply, and the losing retailer has 5 business days to respond; the Registry then records the new trader against the ICP. The ICP is also needed to apply to connect solar or a battery (it is included in the Part 6 application), to request consumption data, and to compare plans using actual usage.
Sending electricity to the grid.
| Question | Answer |
|---|---|
| Can homes export electricity? | Yes |
| Net metering | No |
| Net billing | Yes |
| How exported electricity is paid | Retailer-set buy-back rates per kWh exported, plus, since 1 April 2026, a lines company rebate (negative charge passed through the retailer) for exports at peak times |
| Is net metering available? | No. Imports and exports are measured separately, usually in half-hour intervals. Electricity used on site reduces what the household buys, and exported electricity is paid at the retailer’s buy-back rate, which is normally well below the import price. |
| How much do retailers pay for exports? | Buy-back rates are set by each retailer and are not regulated. Typical published rates are in the range of about 8–17c/kWh, sometimes higher at winter peaks or lower for customers not on the retailer’s own plans. Rates and conditions change frequently, so households compare them on Powerswitch. |
| What is the peak export rebate? | Since 1 April 2026, lines companies must offer a negative charge, credited to the consumer’s retailer, when small consumers inject electricity at peak times. It applies to households and to small businesses with a connection of up to 45 kVA and generation of up to 45 kW. Rates and peak windows vary by network; Powerco, for example, pays about 7c/kWh on weekday mornings and evenings. |
| Are there export limits? | Since 11 May 2026, distributors may not limit the nameplate capacity of systems applying under Parts 1 or 1A, and may not set a maximum export threshold below 10 kW unless a published network study shows a lower limit is needed. Lower limits may be dynamic or flexible, applying only when the network is constrained. From 11 November 2026 such studies must use the Authority’s export limits assessment methodology. |
| Can batteries export? | Yes. Battery storage is declared in the Part 6 application alongside the inverter, and exports from batteries are paid in the same way as solar exports, subject to the retailer’s terms. |
| Is plug-in (balcony) solar allowed? | Not yet. The inverters used by plug-in systems have been prohibited for safety reasons since 2012. In July 2026 the Ministry for Regulation recommended legalising plug-in solar with product certification and output limits; this requires changes to secondary legislation and the Code. |
Connecting a home system.
- Choose an installer; the electrical work must be done or supervised by a registered and licensed electrical worker.
- Apply to the lines company under Part 6 of the Code. Systems of 10 kW or less in total use Part 1, or the simplified one-stage Part 1A if the installation and inverter meet AS/NZS 4777.1:2024 and AS/NZS 4777.2:2020 and the export is within the distributor’s threshold. Larger systems use Part 2. Maximum application fees are NZ$140 (Part 1A) and NZ$310 (Part 1), excluding GST.
- The lines company acknowledges the application within 2 business days and, under Part 1, decides within 30 business days. It must approve a properly made application that meets safety requirements and its published connection and operation standards.
- Install the system with the inverter set to the “Australia A” settings in AS/NZS 4777.2:2020 (or the distributor’s published settings), including volt-watt and volt-var response modes for Part 1A.
- Within 10 business days of approval, send the lines company the Certificate of Compliance issued under the Electricity (Safety) Regulations 2010 and the ICP identifier.
- Ask the retailer for a buy-back arrangement; the MEP reconfigures or replaces the meter so that exports are recorded on a separate register.
Rooftop solar connections are governed by Part 6 of the Code, which sets out regulated application processes, timeframes and maximum fees that every lines company must follow. The rules were strengthened in 2026: the Export Limits amendment from 11 May 2026 stops networks setting blanket export limits below 10 kW without evidence, requires published network studies and maps of constrained areas, and aligns the Part 1A route with the 2024 version of the Australian/New Zealand installation standard.
Payment for exported electricity comes from retailers, and since April 2026 also from lines companies at peak times. There is no feed-in tariff set by government. Because midday wholesale prices have fallen as utility-scale solar has grown, the value of exports depends increasingly on when they happen, which is why the regulator has focused on peak export rebates and time-varying retail plans.
Licensing and approvals.
Requirements depend on the activity. The table sets out what each activity needs and who grants it.
| Activity | Licence or registration | Authority | Notes |
|---|---|---|---|
| Generate electricity | No generation licence. Owners of generation must register as industry participants with the Electricity Authority, except owners of distributed generation under 100 kW. Connection to a local network follows Part 6 of the Code. | Electricity Authority (participant register); lines company | Large plants also need resource consents under the Resource Management Act from regional and district councils, and grid-connected plants need a connection agreement with Transpower. |
| Store electricity (batteries) | No specific storage licence. Grid-scale batteries register as participants and offer energy and reserves like generators. Home batteries are declared in the Part 6 distributed generation application. | Electricity Authority; lines company | Battery installations must meet electrical safety requirements and be certified by a licensed electrical worker. |
| Export to the grid | No licence. Approval from the lines company under Part 6 and a buy-back arrangement with the retailer are needed. | Lines company; retailer | Exporters under 100 kW do not need to register as participants. |
| Sell electricity to consumers (retail) | No supply licence. Retailers register as participants (traders), obtain a participant identifier, meet wholesale prudential requirements and must be members of the Utilities Disputes scheme. | Electricity Authority; Utilities Disputes | Retailers must follow the Code’s switching, metering and consumer data rules. Legislation planned in 2026 would let the Authority set eligibility criteria for new retailers. |
| Sell to a neighbour or tenant (peer-to-peer) | No dedicated framework. Selling electricity to another consumer generally means acting as a trader and registering. Only one trader is normally responsible for an ICP. | Electricity Authority | The Authority granted exemptions for a multiple trading relationships trial with Ara Ake and Kāinga Ora, and consulted on a revised multiple trading relationships proposal in January 2026. |
| Aggregate load or generation | Register as a participant in the relevant class (for example load aggregator or ancillary service agent) to offer aggregated resources into the reserves or wholesale market. | Electricity Authority; Transpower (system operator) | Interruptible load and batteries can be aggregated to a nominated grid exit point to offer instantaneous reserves. |
| Wholesale trading | Purchasers and generators trading in the spot market must be registered participants and meet the clearing manager’s prudential security requirements. | Electricity Authority (market operation service providers) | From 1 July 2026 the four gentailers must supply hedge contracts on non-discriminatory terms. |
| Balancing and reserves | Offer instantaneous reserves (fast and sustained) or other ancillary services through the system operator, as a registered participant meeting Transpower’s technical requirements. | Transpower (system operator) | Interruptible load has been offered into the reserves market for many years; the Rotohiko and Ruakākā batteries are dispatched more often for reserves than for energy. |
| Virtual power plant / remote control of household assets | No separate licence. Control of a household’s battery, EV charger or hot water depends on the contract with the consumer; selling the resulting services in the market requires participant registration. | Electricity Authority | Lines companies have long controlled hot-water cylinders by ripple signal under their network tariffs. |
| Distribution | Register as a distributor participant; revenue and quality are regulated by the Commerce Commission under Part 4 of the Commerce Act (15 lines companies are on the default price-quality path). | Commerce Commission; Electricity Authority | Part 3 of the Electricity Industry Act limits how much generation a distributor may own; Cabinet agreed in October 2024 to remove the 250 MW and 50 MW thresholds. |
| Metering services | Metering equipment providers must register as participants and certify metering installations under Part 10 of the Code. | Electricity Authority | Consumers who own metering only to measure their own ICP do not need to register. |
| Install solar and batteries | Electrical work must be done by registered and licensed electrical workers, who issue a Certificate of Compliance under the Electricity (Safety) Regulations 2010. | Electrical Workers Registration Board; WorkSafe | Most roof-mounted arrays up to 40 m² in wind zones up to High no longer need a building consent (since October 2025). |
New Zealand does not license generators, suppliers or aggregators in the way many countries do. Instead, the Electricity Industry Act 2010 requires anyone participating in the industry to register on the Electricity Authority’s participant register and comply with the Code. Registration is free and online, and only two classes are exempt: owners of distributed generation under 100 kW, and consumers who own the meter at their own connection.
Network businesses are regulated separately by the Commerce Commission. Physical safety is governed by the Electricity (Safety) Regulations 2010 and the licensing of electrical workers, while large generation projects need resource consents from councils.
Flexibility and grid services.
Aggregation of home equipment: Yes
| Market or service | Access for home equipment | Minimum size | Via an aggregator | Detail |
|---|---|---|---|---|
| Instantaneous reserves (fast and sustained) | Yes | — | Yes | Transpower (system operator). Reserves are co-optimised with energy in the spot market to cover the loss of a large generator or the HVDC link. Interruptible load (large industrial and aggregated loads) and grid-scale batteries offer fast (FIR) and sustained (SIR) reserve; aggregation is to a nominated grid exit point. |
| Wholesale energy market | Restricted | — | Limited | Electricity Authority market rules; Transpower dispatch. Grid-scale batteries offer energy like generators. Small distributed resources do not bid directly; households access wholesale value through retailers’ time-varying plans. |
| Network load management (ripple control) | Yes | — | Yes | Lines companies. Lines companies switch off ripple-controlled hot-water cylinders at peak times in exchange for lower tariffs. During the record peak of August 2026, lines companies stood ready to remove controllable load if required. |
| Peak export rebate | Yes | — | No | Lines companies. Since 1 April 2026 lines companies pay a negative charge for injection by small consumers (up to 45 kW of generation) during network peaks, rewarding batteries and solar that export at those times. |
| Transmission and distribution non-network solutions | Developing | — | Yes | Transpower; lines companies. Transpower has tendered for flexibility instead of grid upgrades, for example seeking 63 MW of demand reduction in the upper South Island in the first year, rising to 150 MW by 2031, from batteries, DER and load shifting. The Energy Competition Task Force lists local batteries and flexibility services at grid exit points as a 2026 priority. |
New Zealand’s spot market was one of the first to co-optimise energy and reserves, and interruptible load from industrial users has long provided reserves. Distribution networks also have one of the world’s largest fleets of controllable residential load, because most hot-water cylinders are ripple-controlled. What is less developed is a route for aggregated household batteries, EVs and smart appliances to earn market revenue: most of their value currently comes through retailer plans and the new peak export rebate.
The Electricity Authority is working on multiple trading relationships, which would let a household buy energy from one retailer while selling flexibility through another provider at the same ICP. A revised, simpler proposal was consulted on in January 2026, but it was not in force at the time of writing.
Flexibility and aggregation platforms.
| Platform or aggregator | What it does |
|---|---|
| Electricity Market Information (EMI) | The Electricity Authority’s public data site, with wholesale prices, metering, solar installation and retail market share datasets. |
| Ara Ake | Government-funded energy innovation centre that has run flexibility and multiple trading relationship trials. |
| Powerswitch | Consumer NZ’s comparison site for retail plans, including time-of-use and solar buy-back options. |
Smart meters.
| Fact | Value |
|---|---|
| Smart-meter rollout | Market-led rollout largely complete: about 96% of residential ICPs had an advanced (AMI) meter at the end of August 2026; there is no government mandate or central data hub |
| Reading interval | 30 minutes (half-hourly) |
| Residential ICPs with a smart meter | 1,946,307 of 2,024,588 (96.1%), August 2026 |
| All ICPs with a smart meter | 94.0%, August 2026 |
| Largest residential smart-meter owners | Vector Metering 59%, IntelliHUB 31%, SmartCo 7%, Counties Power 2% |
| Consumer data access | 24 months of data within 5 business days, free of charge (Code clauses 11.32A–11.32B) |
| Open Electricity (Consumer Data Right) | Planned from mid-2027 |
Smart meters were installed from the late 2000s by metering equipment providers working for retailers, without a government mandate. Vector’s metering business and IntelliHUB (which bought Mercury’s Metrix business) own most of them. Each MEP runs its own communications network and sends half-hourly readings to the retailer, which uses them for billing, time-of-use plans and settlement.
Consumers have a legal right to their data: retailers must provide up to 24 months of consumption and export data, including raw meter data, within 5 business days, and may not charge for it. Authorised agents can make the request on a consumer’s behalf. In December 2025 the government designated the electricity retail sector under the Customer and Product Data Act 2025, so that from mid-2027 households with smart meters can direct their data to accredited third parties through standardised interfaces.
Renewable electricity.
Electricity generation mix (2025).
- Hydro: 54.6%
- Geothermal: 21.8%
- Wind: 8.6%
- Solar: 2.2%
- Gas: 8%
- Coal: 3.5%
- Bioenergy, waste heat and other: 1.3%
- Renewable electricity share
- 88.5% (2025)Source 12Share of electricity generation from renewable sources, up from 85.5% in 2024. Renewables exceeded 90% of generation in the June 2026 quarter.
- Home solar
- 85,041 residential ICPs with solar (October 2026)Source 17About 4.2% of residential ICPs (derived against 2,024,588 residential ICPs). Total residential capacity 497.6 MW, an average of 5.9 kW per system.
- Solar added each year
- 285 MW in 2025 (2025)Source 12Derived from MBIE capacity of 545 MW at end 2024 and 830 MW at end 2025. Seven utility-scale plants of 9 MW or more were commissioned in 2025.
- Hydro
- Not identified from a reliable public source.
- Solar PV
- 0.83 GW (end 2025)Source 12
- Wind (onshore)
- 1.265 GW (December 2025)Source 14
- All renewable generation capacity
- 9.149 GW (2025)Source 12Up from 8,781 MW in 2024.
- Grid-scale batteries
- 0.235 GW (May 2026)Source 15435 MWh of storage.
Targets.
- Committed generation pipeline (Electricity Authority, cited by MBIE): 1,705 MW expected within three years, 94% renewable, including 930 MW of solar, 485 MW of wind and 190 MW of geothermal.
Hydro supplies more than half of New Zealand’s electricity, which makes the system sensitive to rainfall and lake levels: in dry years, gas and coal generation at Huntly and elsewhere rises to cover the shortfall, as in 2024. In 2025 favourable inflows and new capacity pushed renewables to 88.5%, with record geothermal output of 9,631 GWh and gas generation at its lowest level since 1981.
Solar is the fastest-growing source. Solar generation rose to a record 959 GWh in 2025, the first solar farm connected directly to the national grid, and further large plants such as the 150 MW Tauhei and 38 MW Omeheu solar farms came online in 2026. Wind generation was 3,811 GWh in 2025, and more wind farms, including Mercury’s Kaiwaikawe in Northland, are under construction.
Security of supply in dry winters is the system’s main weakness, because hydro storage is limited and domestic gas production is declining. The government’s 2025 energy package started procurement of a liquefied natural gas import facility and removed constraints on the majority state-owned generators raising capital for new firming investment.
Energy storage.
- Home batteries
- Not identified from a reliable public source.
- Grid-scale storage
- 0.235 GW (May 2026)Source 15Rotohiko (35 MW / 35 MWh), Ruakākā (100 MW / 200 MWh) and Glenbrook-Ohurua (100 MW / 200 MWh), 435 MWh in total.
Battery storage is new to the New Zealand grid but growing quickly. The three grid-scale batteries in operation in May 2026 totalled 235 MW, and Genesis’s Huntly battery will add 100 MW by the end of 2026. The Electricity Authority reports that batteries mostly charge when renewable output is high and prices low, and discharge at evening peaks, and that two of them have been dispatched more for instantaneous reserves than for energy.
Home batteries are installed alongside rooftop solar, and their value now depends on retailer plans and the peak export rebate rather than any subsidy. There is no national battery incentive.
Storage projects.
- Ruakākā battery (Meridian): 100 MW / 200 MWh battery in Northland, commissioned in 2025; dispatched more often for reserves than for energy.
- Glenbrook-Ohurua battery (Contact): 100 MW / 200 MWh battery at Glenbrook, south Auckland, focused on energy supply; Contact plans a further 200 MW there by 2028.
- Huntly battery (Genesis): 100 MW / 200 MWh battery at Huntly Power Station, due to be commissioned in late 2026.
- Rotohiko battery: 35 MW / 35 MWh battery in the Waikato, the first of the three in operation.
Electricity suppliers.
| Supplier | Market share | Renewable tariff | Time of use | Dynamic | Export tariff |
|---|---|---|---|---|---|
| Mercury | 24.7% of ICPs (August 2026) | Unknown | Yes | No | Yes |
| Genesis Energy | 20.4% of ICPs (August 2026) | Unknown | Yes | No | Yes |
| Contact Energy | 19.9% of ICPs (August 2026) | Unknown | Yes | No | Yes |
| Meridian Energy | 12.9% of ICPs, plus 6.1% under its Powershop brand (August 2026) | Unknown | Yes | Unknown | Yes |
| Electric Kiwi | 3.1% of ICPs (August 2026) | Unknown | Yes | No | Unknown |
| Nova Energy | 3.1% of ICPs (August 2026) | Unknown | Unknown | No | Unknown |
| Pulse Energy | 3.4% of ICPs (August 2026) | Unknown | Unknown | No | Unknown |
| Octopus Energy | 0.3% of ICPs (August 2026) | Unknown | Yes | Unknown | Unknown |
The retail market is dominated by the four gentailers, which together with Meridian’s Powershop brand supplied about 84% of ICPs in August 2026. Independent retailers such as Pulse, Electric Kiwi, Nova, Switch and Ecotricity make up most of the rest. Market shares above are of all ICPs (residential and business) and are calculated from the Electricity Authority’s network-region dataset.
Product details change often, so the table shows broad availability only; “Unknown” means it was not verified for this profile. Under the Authority’s 2026 rules, retailers with more than 5% of the market must offer time-varying pricing plans.
Key organisations.
| Organisation | Category | What it does | Why it matters |
|---|---|---|---|
| Ministry of Business, Innovation and Employment | Government | Energy policy and statistics | Publishes Energy in New Zealand, the Quarterly Survey of Domestic Electricity Prices and Consumer Data Right policy. |
| Electricity Authority | Regulator | Electricity market regulator | Writes and enforces the Code, runs the Registry and participant register, and publishes EMI market data. |
| Commerce Commission | Regulator | Network monopoly regulator | Sets revenue limits for Transpower and lines companies (DPP4, 2025–2030). |
| Transpower New Zealand | Transmission | Grid owner and system operator | Operates the national grid, dispatch and reserves markets. |
| Electricity Networks Aotearoa | Distribution | Lines company industry body | Represents all 29 electricity distribution businesses. |
| Energy Efficiency and Conservation Authority (EECA) | Government | Energy efficiency agency | Runs Warmer Kiwi Homes insulation and heat pump grants. |
| NZ Wind Energy Association | Renewable Energy | Wind industry body | Publishes data on operating and planned wind farms. |
| Sustainable Energy Association New Zealand (SEANZ) | Solar | Solar and distributed energy industry body | Represents solar, storage and distributed energy businesses. |
| Ara Ake | Flexibility | Energy innovation centre | Runs trials of flexibility and multiple trading relationships. |
| Utilities Disputes (Tautohetohe Whaipainga) | Consumer | Statutory disputes scheme | Resolves complaints about retailers and lines companies; membership is compulsory. |
| Consumer NZ Powerswitch | Consumer | Independent price comparison | Compares retail plans and helps consumers switch. |
Technical standards.
| Area | Standard | Issued by | Notes |
|---|---|---|---|
| Grid connection (installation) | AS/NZS 4777.1:2024 | Standards Australia / Standards New Zealand | Installation of inverter energy systems; required for the simplified Part 1A connection route since 11 May 2026. |
| Inverters / anti-islanding | AS/NZS 4777.2:2020 (incl. Amendments 1 and 2) | Standards Australia / Standards New Zealand | Low-voltage inverters must comply with and apply the “Australia A” settings (Code clause 6.3B) unless the distributor publishes alternative settings within the allowed range; a Declaration of Conformity from an IANZ-recognised laboratory is needed for Part 1A. |
| Distributed generation connection rules | Electricity Industry Participation Code, Part 6 | Electricity Authority | Regulated application processes, timeframes, export limits and maximum fees for distributed generation. |
| Wiring | AS/NZS 3000 (Wiring Rules) | Standards Australia / Standards New Zealand | Joint Australian/New Zealand Wiring Rules for electrical installations. |
| PV arrays | AS/NZS 5033 | Standards Australia / Standards New Zealand | Joint standard for installation and safety of the DC side of PV arrays. |
| Batteries / fire | AS/NZS 5139 | Standards Australia / Standards New Zealand | Joint standard for the safety of battery systems used with power conversion equipment. |
| Electrical safety certification | Electricity (Safety) Regulations 2010 | WorkSafe / Electrical Workers Registration Board | Licensed electrical workers issue a Certificate of Compliance, which must be given to the distributor within 10 business days of Part 6 approval. |
| Building | Building (Exempt Roof-mounted Solar Panel Arrays and Building Work) Order 2025 | MBIE | Roof-mounted arrays up to 40 m² in wind zones up to High are exempt from building consent; larger arrays or higher wind zones need design by a chartered professional engineer. |
Permissions.
| Permission | Required | Level | Detail |
|---|---|---|---|
| Lines company approval (Part 6) | Yes | Regional | Needed for every grid-connected solar, battery or other distributed generation system, under the regulated Part 1, 1A or 2 process. |
| Building consent | Limited | National | Not needed for most roof-mounted arrays up to 40 m² in wind zones up to High since October 2025; larger arrays can be exempt if designed by a chartered professional engineer. Building Code compliance still applies. |
| Resource consent | Limited | Local | Rooftop solar is usually permitted under district plans, but heritage areas and ground-mounted or large systems may need consent. |
| Certificate of Compliance | Yes | National | Issued by the licensed electrical worker and sent to the lines company within 10 business days of approval. |
| Participant registration | No | National | Not required for owners of distributed generation under 100 kW. |
| Retailer buy-back agreement | Limited | National | Needed to be paid for exports; terms are set by the retailer. |
For a typical home system the key approval comes from the lines company, which must follow the Code’s timeframes and may charge only the prescribed maximum fees. Building consent has largely been removed for rooftop arrays, and the Ministry for Regulation’s 2026 review recommended further steps to speed up approvals, including letting accredited installers sign off plug-in systems.
Support schemes, taxes and incentives.
| Scheme | Status | Type | Detail | Period |
|---|---|---|---|---|
| Peak export rebate (distribution pricing) | Active | Export payment | Lines companies must offer a negative charge, credited through the retailer, for electricity injected at peak times by households and small businesses (connections up to 45 kVA, generation up to 45 kW). Rates and peak periods vary by network. | From 1 Apr 2026 |
| Warmer Kiwi Homes | Active | Grant | EECA grants for ceiling and underfloor insulation (90% of cost for Community Services Card or SuperGold Combo holders and high-need areas, 80% or 50% elsewhere) and for high-wall heat pumps (up to 90%, maximum NZ$3,450) for owner-occupiers of pre-2008 homes. Wood and pellet burner grants have ended. | — |
| Low Fixed Charge tariff option | Active | Regulated tariff option | Retailers must offer low users a plan with a capped daily fixed charge. The cap has risen each April during a five-year phase-out, and the regulations end on 1 April 2027. | Phase-out from 2022; ends 1 Apr 2027 |
Data and connectivity.
- Fixed broadband
- 38 fixed broadband subscriptions per 100 people (2024)Source 45
- 4G coverage
- Not identified from a reliable public source.
- 5G coverage
- Not identified from a reliable public source.
Smart meters communicate through networks run by each metering provider rather than a central system. Home internet matters for distributed energy because flexible or dynamic export limits under the 2026 Part 6 rules depend on inverters that can receive signals, and because time-of-use and battery-optimisation services rely on app and cloud connections. Lines companies also use their own ripple-control signals, sent over the power lines, to switch hot-water load.
Grid conditions.
- National peak demand
- 7.415 GW (August 2026 (record))Source 35New national record of 7,415 MW during a cold morning peak, beating the previous record of 7,247 MW (Transpower).
- Annual electricity demand
- 40.6 TWh (2025)Source 12Electricity consumption, up 1.3% on 2024. Generation was 44.14 TWh.
- Generation capacity
- Not identified from a reliable public source.
- Interconnection
- 0 GW (international)New Zealand has no international interconnectors. The HVDC link connects the South and North Islands within the national grid.
- Curtailment
- Not identified from a reliable public source.
The national grid is stretched in two ways. Winter peaks are rising with electric heating and growth in industrial use: demand set a new record of 7,415 MW in August 2026, when cold weather and low wind tightened the system and large users reduced demand. And in dry years the hydro-heavy system needs thermal back-up, while domestic gas supply is falling, which is why firming capacity, batteries and an LNG import option are policy priorities.
Most of the new solar farms and the largest wind farms are in the North Island, where most demand is. Transpower and the lines companies are increasingly using flexibility tenders and batteries to defer network upgrades, and the Commerce Commission’s 2025–2030 price paths fund substantial network investment.
Grid and capacity maps.
Regulatory changes.
| Change | Status | Date | Detail |
|---|---|---|---|
| Peak export rebate | Current | 1 April 2026 | Lines companies must pay small consumers (up to 45 kW of generation) a negative charge for exporting at peak times, credited through their retailer. |
| Export Limits amendment to Part 6 | Current | 11 May 2026 | No nameplate limits for small systems; export thresholds below 10 kW only with a published network study; updated AS/NZS 4777.1:2024 requirement for Part 1A. |
| Time-varying pricing obligation | Current | 30 June 2026 (further obligations from 1 October 2026) | Retailers with more than 5% market share must offer time-varying pricing plans to households and small businesses. |
| Non-discrimination obligations on gentailers | Current | 1 July 2026 | Contact, Genesis, Mercury and Meridian must supply and price hedge contracts even-handedly to all buyers, including their own retail arms, and carry out retail price consistency assessments. |
| Export limits assessment methodology | Upcoming | 11 November 2026 | Network studies used to justify export limits below 10 kW, or to assess larger applications, must use the Authority’s methodology and be published. |
| Strengthened Electricity Authority powers | Upcoming | Legislation in 2026 | Planned amendments to the Electricity Industry Act would raise maximum Code penalties to NZ$10 million or three times the commercial gain, add an offence for misleading the Authority, and let it suspend participants and set entry criteria for retailers. |
| End of Low Fixed Charge regulations | Upcoming | 1 April 2027 | Retailers will no longer be required to offer a low fixed charge plan to low users. |
| Improving Electricity Billing Code amendment | Upcoming | 1 April 2027 (deferred from 30 October 2026) | New billing requirements for retailers; commencement deferred to give retailers time to change their systems. |
| Open Electricity (Consumer Data Right) | Upcoming | Mid-2027 | Households and small businesses with smart meters will be able to share their electricity data with accredited third parties; retailers must share product and pricing information. |
| Plug-in solar legalisation | Upcoming | Recommended July 2026; timing not confirmed | The Ministry for Regulation recommended removing the prohibition on plug-in solar inverters with product certification and output limits. |
| Multiple trading relationships | Upcoming | Revised proposal consulted January 2026 | Would let consumers use more than one provider at the same ICP, for example for energy and flexibility services. No final in-force date had been confirmed. |
Market indicators.
Neutral descriptions of the market, each with the evidence behind it. They do not rank countries.
| Indicator | Level | Basis |
|---|---|---|
| Electricity cost | Medium | Low below €0.15 per kWh, high at €0.30 or more (household price including taxes, converted to euros). |
| Household electricity use | High | Low below 2,500 kWh a year, high at 5,000 kWh or more (average use per household). |
| Renewable share | High | Low below 30%, high at 60% or more (renewable share of electricity). |
| Smart-meter adoption | High | Low below 30%, high at 80% or more (share of meters that are smart). |
| Home solar adoption | Low | 85,041 residential ICPs with solar in October 2026, about 4.2% of residential connections, averaging 5.9 kW. |
| Distributed energy market | Medium | Heat pumps are a main heating type in 66.8% of dwellings and most hot-water cylinders are ripple-controlled, but battery EVs are 1.9% of the fleet and home battery numbers are not published. |
| Grid flexibility market | Medium | Long-established reserves market with interruptible load and aggregation to grid exit points, extensive network ripple control and a new peak export rebate; no market route yet for aggregated household batteries beyond retailer plans. |
| Energy storage adoption | Low | 235 MW / 435 MWh of grid-scale batteries in May 2026 against a 7.4 GW peak; no official home battery count. |
| Renewable growth environment | Medium | Renewable share already high (88.5% in 2025); renewable capacity grew from 8,781 MW to 9,149 MW in 2025 and solar by 52%, with a 1,705 MW committed pipeline that is 94% renewable. |
Sources.
Public sources used for this profile, with the date each was accessed.
Show all 46 sources
- Consumer awareness of Utilities Disputes and Powerswitch services. Electricity Authority, 2020. accessed 1 October 2026.
- National population estimates: At 30 June 2026. Stats NZ, 2026. accessed 1 October 2026.
- 2023 Census data release (household and home ownership figures). BERL (reporting Stats NZ 2023 Census data), 2024. accessed 1 October 2026.
- Families, households, and housing: 2023 Census. Stats NZ, 2024. accessed 1 October 2026.
- Renting households by type of landlord, 2018 and 2023 Census. Figure.NZ (Stats NZ data), 2023. accessed 1 October 2026.
- Occupied dwellings in New Zealand by dwelling type, 2023 Census. Figure.NZ (Stats NZ data), 2023. accessed 1 October 2026.
- Average residential electricity consumption per household in New Zealand. Figure.NZ (MBIE Sales-based Electricity Costs, June 2025), 2025. accessed 1 October 2026.
- Quarterly Survey of Domestic Electricity Prices – 15 August 2026. Ministry of Business, Innovation and Employment, 2026. accessed 1 October 2026.
- Quarterly Survey of Domestic Electricity Prices – 15 August 2022. Ministry of Business, Innovation and Employment, 2022. accessed 1 October 2026.
- Quarterly Survey of Domestic Electricity Prices – 15 August 2021. Ministry of Business, Innovation and Employment, 2021. accessed 1 October 2026.
- ECB euro reference exchange rate: New Zealand dollar (NZD). European Central Bank, 2026. accessed 1 October 2026.
- Energy in New Zealand 2026 (2025 calendar year edition). Ministry of Business, Innovation and Employment, 2026. accessed 1 October 2026.
- Utility-scale projects drive New Zealand’s solar rollout. pv magazine, 2026. accessed 1 October 2026.
- Operating onshore wind farm projects. NZ Wind Energy Association, 2025. accessed 1 October 2026.
- Eye on electricity: battery performance in New Zealand. Electricity Authority, 2026. accessed 1 October 2026.
- Metering snapshot – AMI meters by MEP parent company, residential, New Zealand, 31 August 2026. Electricity Authority (EMI), 2026. accessed 1 October 2026.
- Solar installations dataset (by region and market segment). Electricity Authority (EMI), 2026. accessed 1 October 2026.
- Market share trends by network reporting region (to 31 August 2026). Electricity Authority (EMI), 2026. accessed 1 October 2026.
- Electricity Industry Participation Code 2010 – Part 11 Registry information management (1 October 2026). Electricity Authority, 2026. accessed 1 October 2026.
- Electricity Industry Participation Code 2010 – Part 6 Connection of distributed generation (1 September 2026). Electricity Authority, 2026. accessed 1 October 2026.
- Registry manager. Electricity Authority, 2026. accessed 1 October 2026.
- Participant register – FAQs. Electricity Authority, 2026. accessed 1 October 2026.
- Task Force package two guidance resources now available. Electricity Authority, 2026. accessed 1 October 2026.
- Requiring distributors to pay a rebate when consumers supply electricity at peak times: definition of a small business. Electricity Authority, 2026. accessed 1 October 2026.
- Electricity Industry Participation Code (Non-Discrimination Obligations and Associated Amendments) Amendment 2026. Electricity Authority, 2026. accessed 1 October 2026.
- Next steps on multiple trading relationships and switching. Electricity Authority, 2025. accessed 1 October 2026.
- Code amendment deferring the Improving Electricity Billing Amendment 2026. Electricity Authority, 2026. accessed 1 October 2026.
- Electricity Industry Participation Code Amendment (Improving Consumer Access to their Electricity Information) 2025. Electricity Authority, 2025. accessed 1 October 2026.
- Open electricity (Consumer Data Right policy design). Ministry of Business, Innovation and Employment, 2026. accessed 1 October 2026.
- Unpacking the energy package: a roadmap to the energy reform. MinterEllisonRuddWatts, 2025. accessed 1 October 2026.
- Advancing the energy package: expanding the Electricity Authority’s mandate. Russell McVeagh, 2026. accessed 1 October 2026.
- Investigating options to amend or remove the amount of generation that electricity distribution businesses may own – minute of decision. Ministry of Business, Innovation and Employment, 2024. accessed 1 October 2026.
- 2025–2030 electricity default price-quality path. Commerce Commission, 2024. accessed 1 October 2026.
- The electricity industry. Electricity Networks Aotearoa, 2026. accessed 1 October 2026.
- New Zealand power demand hits record as cold snap bites. InfrastructureNews (reporting Transpower), 2026. accessed 1 October 2026.
- Transpower seeks proposals for electricity flexibility services in the upper South Island. Transpower, 2024. accessed 1 October 2026.
- Main types of home heating (2023 Census). Environmental Health Intelligence New Zealand (Massey University), 2025. accessed 1 October 2026.
- Number of motor vehicles (fleet statistics to 2024). Environmental Health Intelligence New Zealand (Massey University), 2025. accessed 1 October 2026.
- Warmer Kiwi Homes: what can I get funding for?. Energy Efficiency and Conservation Authority, 2026. accessed 1 October 2026.
- Consent or not? Roof-mounted solar panel exemption. Simpli (council building consent guidance), 2025. accessed 1 October 2026.
- We’re legalising it: plug-in solar. The Spinoff, 2026. accessed 1 October 2026.
- How to read your power bill. Consumer NZ Powerswitch, 2026. accessed 1 October 2026.
- Flick Electric sale to Meridian: what to do if you’re a customer. Consumer NZ, 2025. accessed 1 October 2026.
- Urban population (% of total population) – New Zealand. World Bank, 2025. accessed 1 October 2026.
- Fixed broadband subscriptions (per 100 people) – New Zealand. World Bank / ITU, 2024. accessed 1 October 2026.
- Electric power consumption (kWh per capita) – New Zealand. World Bank, 2024. accessed 1 October 2026.
Questions about energy in New Zealand.
MBIE’s survey of advertised plans put the national average at 42.1 cents per kWh including GST in August 2026, for a household using 8,000 kWh a year. Prices vary by network area, from about 37c in Wellington to 51c in Balclutha. There is no regulated price cap.
The ICP (installation control point) identifier: a 15-character code made up of a 10-digit number, a two-letter distributor code and a three-character checksum. It is created by the lines company, held in the national Registry, stays with the property and is printed on the power bill.
Yes. Once the lines company approves the system under Part 6 of the Code, the retailer pays a buy-back rate for exported electricity, and since 1 April 2026 lines companies also pay a rebate for exports at peak times. There is no net metering or government feed-in tariff.
Transpower owns the national grid and is the system operator. Local networks are owned by 29 lines companies such as Vector, Powerco and Orion. The Electricity Authority sets the market rules and the Commerce Commission regulates network charges.
You need approval from your lines company and a Certificate of Compliance from a licensed electrician. Since October 2025, most roof-mounted arrays up to 40 m² in wind zones up to High do not need a building consent.
Almost all do: about 96% of residential connections had an advanced meter in August 2026. Retailers must give you up to 24 months of your half-hourly data within 5 business days, free of charge.
Mostly. In 2025, 88.5% of electricity came from renewable sources: about 55% hydro, 22% geothermal, 9% wind and 2% solar. Gas and coal supplied most of the rest.