How electricity works in Netherlands: prices, the grid and local rules. Olmack status: Not yet available. Information last checked 1 October 2026.

Olmack in Netherlands: Not yet available.Olmack is not offered in Netherlands yet. The market information on this page is provided for reference. Information last checked 1 October 2026.
Energy-market overview

How electricity works in Netherlands.

Netherlands electricity market 2026: prices and energy tax, EAN codes, netbeheerders, smart meters, end of net metering in 2027, grid congestion, licensing and flexibility.

This overview covers what electricity costs, how much a typical household uses, how the grid is run and regulated, and whether homes can send electricity back to the grid. Figures are shown in Euro (EUR) where they relate to prices.

Each important figure links to its public source and states the year it refers to. Where no reliable public figure was found, the page says so. Unfamiliar terms are explained in our glossary.

At a glance

Netherlands energy at a glance.

Key figures for households in Netherlands. Each one links to its source on the full overview below.

  • Electricity price.

    0.258 EUR per kWh for households, including taxes. Figures for August 2026.

  • Household use.

    2,580 kWh a year for a typical household. Figures for 2025.

  • Renewable share.

    48.5% of electricity from renewable sources. Figures for 2025.

  • Selling back to the grid.

    Can homes export electricity? Yes. Details are in the export section below.

Before you start

Four things to check in Netherlands.

Rules and schemes change. Use this page as a starting point, then confirm the details that matter to you.

  1. Check the local rules.

    Read the connection, export and permission rules for Netherlands below, and ask your local grid operator if anything is unclear.

  2. Choose a qualified installer.

    Look for an installer listed on an official register, with the certifications Netherlands requires for the work.

  3. Look at current schemes.

    Check which support schemes are open now. Closed or scheduled schemes are labelled as such.

  4. Talk to your energy supplier.

    Ask how new equipment, such as solar or a battery, could affect your tariff and any export payments.

Local detail

Schemes, rules and certifications in Netherlands.

The full detail sits in the sections below. Each item shows its status and links to the official source.

  • Support schemes.

    Grants, tax relief and export payments in Netherlands, each labelled Active, Scheduled or Closed.

  • Connection and export.

    How equipment is connected to the grid in Netherlands, and the steps to export electricity.

  • Standards and certifications.

    The technical standards and installer certifications that apply to energy equipment in Netherlands.

Full overview

The energy market in Netherlands, in detail.

Each figure shows the year it refers to and a numbered link to its public source, listed at the end of the page.

Profile last updated 1 October 2026.

On this page22 sections

The Netherlands has a fully liberalised electricity market. Households choose from dozens of licensed suppliers, while the high-voltage grid is run by the state-owned transmission system operator TenneT and the local networks by six regional network operators (netbeheerders), of which Liander, Enexis and Stedin are by far the largest. The Authority for Consumers and Markets (ACM) regulates the sector. On 1 January 2026 the new Energiewet (Energy Act) replaced the Electricity Act 1998 and the Gas Act.

Household electricity is dominated by taxes and fixed network charges. In August 2026 the average variable price for a new or existing variable contract, including energy tax and VAT, was about €0.258 per kWh, with a fixed network (transport) charge of around €477 a year largely offset by an energy tax credit of €629 a year per connection.

Rooftop solar is unusually widespread: more than three million homes had solar panels at the end of 2025, and solar supplied almost a fifth of Dutch electricity generation. The net-metering scheme (salderingsregeling) that made this possible ends on 1 January 2027, and full local grids (netcongestie) now limit new and upgraded connections across much of the country.

Energy snapshot.

Headline figures for electricity in Netherlands. Each shows its data year and links to its source.

  • Population18,130,208 peopleSource 21 January 2026
  • Households8,475,000 private householdsSource 21 January 2026
  • Average household size2.1 people/householdSource 21 January 2026
  • Electricity use per household2,580 kWh/yrSource 32025
  • Household price (EUR)0.258 EUR/kWhSource 1August 2026
  • Renewable electricity share48.5%Source 62025
  • Solar capacity29.4 GWpSource 7end 2025
  • Wind capacity11.8 GWSource 6end 2025
  • Energy storage capacity0.35 GWSource 9end 2024
  • Smart-meter share94%Source 18January 2026
Market structure
Fully liberalised
Homes can export to the grid
Yes
Home equipment in grid services
Developing
Regulator
Autoriteit Consument & Markt (ACM)
System operator
TenneT TSO
Distribution networks
Six regional network operators (netbeheerders): Liander, Enexis and Stedin cover most of the country; Westland Infra, Rendo and Coteq serve small areas
Currency
Euro (EUR)
Voltage and frequency
230 V / 50 Hz

Electricity prices in Netherlands.

Household price (EUR)
0.258 EUR/kWh (August 2026)Source 1CBS weighted average variable supply price for fixed and variable contracts (€0.1469/kWh) plus energy tax (€0.11085/kWh), both including 21% VAT. Excludes the fixed transport charge (€476.87/yr), fixed supply charge (€114.63/yr) and the energy tax credit (−€628.96/yr).
Typical annual electricity bill
628 EUR/yr (August 2026 prices, 2025 consumption)Source 1Derived: 2,580 kWh × €0.2578/kWh + transport €476.87 + fixed supply €114.63 − energy tax credit €628.96, all including VAT. Electricity only, for an average home without solar panels on an average variable contract.

Household price trend (EUR per kWh).Source 1

0.2230.3290.4352021Aug 2026
Netherlands household electricity price, EUR per kWh
20210.2229 EUR/kWh
20220.2865 EUR/kWh
20230.4346 EUR/kWh
20240.3026 EUR/kWh
20250.2746 EUR/kWh
Jan 20260.2606 EUR/kWh
Apr 20260.2492 EUR/kWh
Aug 20260.2578 EUR/kWh

What makes up the price

A Dutch electricity bill has three parts. The supplier charges a fixed monthly amount and a price per kWh for the energy itself. The network operator’s transport charge is a fixed annual amount that depends on the connection size; CBS puts the average at €476.87 a year including VAT in 2026. The government adds energy tax per kWh, which in 2026 is €0.09161/kWh before VAT (€0.11085 with VAT) in the first consumption band, and gives every household connection a fixed energy tax credit (vermindering energiebelasting) of €519.80 before VAT (€628.96 with VAT). VAT of 21% applies to everything.

Because the tax credit roughly cancels out the fixed network and supply charges, the price per kWh is what really drives a household’s bill. In August 2026 the average variable supply price was €0.1469/kWh with VAT, which together with energy tax gives about €0.258/kWh.

Trend

Average prices rose sharply in 2022 and peaked in 2023, when the average contract price including taxes reached about €0.43/kWh; in that year a temporary government price cap (prijsplafond) limited what households actually paid for part of their consumption. Prices have since fallen back to around €0.25–0.26/kWh in 2026, helped by lower wholesale prices and a cut in energy tax on electricity in 2026. Fixed transport charges, by contrast, have risen every year as network operators invest in grid expansion: from €253.88 a year in 2022 to €476.87 in 2026.

Feed-in costs

Many suppliers now charge customers with solar panels a fee per kWh fed back (terugleverkosten). ACM investigated these charges in 2025 and concluded they were not unreasonably high, but asked suppliers to charge them uniformly as an amount per kWh fed back so that contracts can be compared. After net metering ends in 2027 suppliers may only charge costs that reflect what processing feed-in actually costs them.

Tariff types.

Tariff types.
TariffAvailableDetail
VariableYesVariable-price contracts of indefinite duration, where the supplier can change the price (usually monthly or quarterly) with advance notice. Under the Energiewet every licensed supplier must offer an ACM model contract with variable rates.
FixedYesFixed-price contracts, usually for one to three years. Since 1 January 2026 suppliers must offer at least a one-year fixed model contract, and may only charge an early termination fee if it is clearly stated in the contract.
DynamicYesDynamic contracts follow day-ahead wholesale prices, so the unit price changes through the day and can turn negative before taxes. ACM counted 423,000 consumers on a dynamic electricity contract on 1 January 2025 (about 6% of households), offered by 32 suppliers. In August 2026 the average dynamic supply price was €0.1716/kWh including VAT, before energy tax.
Off-peakLimitedTraditional day/night (normaal/dal) metering with two registers still exists on many contracts, but the night rate differs only slightly from the day rate because energy tax and network charges do not vary by time of day.
Time-of-useLimitedNetwork charges for households are currently a flat annual amount based on connection size. The network operators have proposed time- and volume-dependent transport tariffs for small consumers, which ACM expects to introduce in 2029.
RegulatedNoThere is no regulated end-user price. ACM supervises supplier tariffs for reasonableness, and the government price cap (prijsplafond) applied only in 2023.

Household prices compared with neighbouring countries (EUR per kWh).

Household prices including taxes, converted to euros as stated on each country page.

Household electricity use.

Electricity use per household
2,580 kWh/yr (2025)Source 3Average electricity delivered from the grid to a private dwelling. After subtracting electricity fed back by homes with solar panels, the average net delivery was 1,810 kWh. Apartments averaged 1,830 kWh.
Average daily use per household
7.1 kWh/day (2025)Source 3Derived: 2,580 kWh average delivery per dwelling divided by 365.
Typical household peak demand
Not identified from a reliable public source.
Electricity use per person
6,386 kWh/person/yr (all sectors) (2024)Source 14
Heat pumps
829,776 hydronic heat pumps in homes (end 2025)Source 10Air-to-water (661,434) plus ground- or water-source (168,342) heat pumps in dwellings. Including 1,738,018 air-to-air units, the total was 2,567,794.
Air conditioning
Not identified from a reliable public source.
Electric vehicles
770,453 battery-electric passenger cars (August 2026)Source 128.2% of all passenger cars. Electric cars were 40% of new car sales in 2026 to date.
Electric cooking
Not identified from a reliable public source.

Average household electricity use is modest by north-western European standards because most homes are heated by natural gas. CBS measured average delivery from the grid of 2,580 kWh per dwelling in 2025, ranging from 1,830 kWh for apartments to 2,760 kWh for some house types. Because so many homes have solar panels, average net delivery after feed-in was only 1,810 kWh.

Electrification is changing this. CBS counted almost 830,000 air-to-water and ground-source heat pumps in homes at the end of 2025, alongside about 1.74 million air-to-air units, and 770,000 fully electric cars were on the road by August 2026. The share of homes on district heating rose to 7.4% in 2025. Homes that replace a gas boiler with a heat pump, or charge an EV at home, typically need a larger connection, which is now difficult to obtain in congested areas.

Housing and households.

Dwellings
8,274,480 dwellings (31 December 2024)Source 4
Owner-occupied
57.5 % of dwellings (31 December 2024)Source 4Derived: 4,754,055 owner-occupied dwellings out of 8,274,480.
Private rented
14.3 % of dwellings (31 December 2024)Source 4Derived: 1,180,685 dwellings owned by landlords other than housing associations.
Social or public housing
28.2 % of dwellings (31 December 2024)Source 4Derived: 2,331,465 dwellings owned by housing associations (woningcorporaties).
Houses
63 % of dwellings (single-family homes) (31 December 2024)Source 4Derived: 5,211,310 eengezinswoningen (detached, semi-detached and terraced houses).
Apartments and flats
37 % of dwellings (multi-family) (31 December 2024)Source 4Derived: 3,063,165 meergezinswoningen.
Urban population
95.9 % of population (2025)Source 13

Almost two-thirds of Dutch dwellings are single-family houses, most of them terraced (rijtjeshuizen) with a pitched or flat roof, which is one reason rooftop solar spread so quickly. Apartments make up 37% of the stock and dominate in Amsterdam, Rotterdam, The Hague and Utrecht.

Tenure strongly affects who can install solar panels, batteries or heat pumps. At the end of 2024, 57.5% of dwellings were owner-occupied, 28.2% belonged to housing associations and 14.3% to other landlords. Housing associations run their own large-scale insulation, solar and heat pump programmes, while private tenants usually need landlord consent. About 18% of dwellings were built before 1945 and a further 37% between 1945 and 1980, before modern insulation standards.

How the grid works in Netherlands.

  1. TransmissionTenneT TSO
  2. DistributionSix regional network operators (netbeheerders): Liander, Enexis and Stedin cover most of the country; Westland Infra, Rendo and Coteq serve small areas
  3. MeteringEnergie Data Services Nederland (EDSN), Network operators (regulated metering)
  4. Supply6 or more retail suppliers

Physical flow

Large power stations, offshore wind farms and interconnectors with Belgium, Germany, Great Britain, Norway and Denmark feed TenneT’s 380 kV and 220 kV grid and its 150 kV and 110 kV regional high-voltage networks. Regional network operators take power from TenneT substations into medium-voltage networks (typically 10–20 kV) and then, through neighbourhood substations, into the 400/230 V low-voltage network. A typical home has a 1×25 A to 1×40 A single-phase or a 3×25 A three-phase connection; all connections up to 3×80 A count as small consumer (kleinverbruik) connections.

Liander serves most of North Holland, Gelderland, Flevoland and Friesland; Enexis serves Groningen, Drenthe, Overijssel, North Brabant and Limburg; and Stedin serves most of South Holland, Utrecht and Zeeland. Westland Infra, Rendo and Coteq have small service areas.

Commercial flow

Suppliers buy electricity from producers, bilaterally or on EPEX SPOT and Nord Pool, and are responsible for keeping their portfolio in balance through a balance-responsible party (BRP). TenneT settles imbalances and buys balancing reserves from balancing service providers (BSPs). The household receives a single bill from the supplier, which includes the network operator’s transport charge and the energy tax.

The Energiewet

The Energiewet, in force since 1 January 2026, replaced the Electricity Act 1998 and Gas Act with one framework based on EU rules. It gives legal roles to active customers, aggregators, energy communities and peer-to-peer traders, allows energy sharing between customers of the same supplier, strengthens ACM’s powers over suppliers, and requires every household meter to measure consumption and feed-in separately, which means the remaining old meters must be replaced.

Who does what.

Who does what.
RoleOrganisationWhat it does
MinistryMinistry of Climate and Green Growth (KGG)Responsible for energy policy and legislation, including the Energiewet, offshore wind planning, the ending of net metering and subsidy schemes such as ISDE and SDE++ (run by RVO).
RegulatorAutoriteit Consument & Markt (ACM)Grants supply licences, sets network tariffs and the technical codes (grid, metering and tariff codes), supervises supplier prices, feed-in charges and consumer protection, and sets the priority rules for scarce grid capacity.
TSOTenneT TSOState-owned operator of the national high-voltage grid (110 kV and above) and the offshore grid connecting North Sea wind farms. Responsible for system balance, procuring FCR, aFRR and mFRR reserves and managing the national connection queue.
DSORegional network operators (netbeheerders)Liander, Enexis, Stedin, Westland Infra, Rendo and Coteq own and operate the regional networks in their areas. They connect customers, install and own household meters, read them and pass meter data to suppliers. Under the Energiewet they are formally called distribution system operators (distributiesysteembeheerders).
Data hub / registryEnergie Data Services Nederland (EDSN)Joint platform of the network operators that keeps the central connection register (the EAN-codeboek), handles switching and moving-house messages, and distributes meter data between network operators, suppliers and other market parties.
MeteringNetwork operators (regulated metering)For small connections the regional network operator is responsible for placing, maintaining and reading the meter. Households cannot choose a meter company.
SupplierLicensed energy suppliersSuppliers need an ACM licence to supply households and small businesses. They buy power, are balance-responsible (or contract a balance-responsible party), bill the customer for energy, network charges and taxes, and must offer ACM model contracts.
ExchangeEPEX SPOT and Nord Pool (Dutch bidding zone)The Netherlands is one bidding zone coupled to the European day-ahead and intraday markets. Day-ahead prices are the basis of dynamic household contracts.
Flexibility marketGOPACSPlatform run jointly by TenneT and the regional network operators for congestion management: redispatch bids and capacity-limitation contracts (CSC) with grid users and aggregators.

Compared with the UK system.

Compared with the UK system.
UK conceptNetherlands equivalentHow it works
DNORegionale netbeheerder (distributiesysteembeheerder)Six regional network operators, each a monopoly in its area. Your operator is fixed by your address. It owns the connection and the meter, handles outages and connection requests, and charges a fixed annual transport charge through your supplier’s bill.
National Grid/NESOTenneTTenneT is both owner and operator of the national high-voltage grid and the offshore grid, and acts as system operator and balancing authority. There is no separate system operator as in Great Britain.
MPANEAN-code (electricity)An 18-digit number identifying each electricity connection, assigned by the network operator and held in the national EAN-codeboek managed by EDSN. It stays with the address when the occupant, supplier or meter changes.
MPRNEAN-code (gas)Gas connections have their own separate 18-digit EAN code in the same register. Homes with both gas and electricity therefore have two EAN codes.
Meter operatorNetbeheerder (regulated)There is no competitive meter operator market for households. The regional network operator installs, owns, maintains and reads the meter as a regulated task.
SupplierEnergieleverancier (ACM licence)Competitive retail market with free switching. Suppliers need an ACM supply licence for small consumers and must offer model contracts; there is no price cap.
Smart-meter infrastructureNetwork-operator smart metersEach network operator rolls out and reads its own smart meters; there is no national communications company like DCC. Readings are passed through the network operators’ shared EDSN systems to suppliers. A local P1 port lets households and devices read live data.

How a supply point is identified.

871234567890123456 (fictional)

Fictional example in the real format.

How a supply point is identified.
QuestionAnswer
What is it called?EAN-code (aansluiting) (EAN)
Who issues it?The regional network operator (Liander, Enexis, Stedin, Westland Infra, Rendo or Coteq) when the connection is created
FormatAn 18-digit numeric identifier built on the GS1 Global Service Relation Number scheme: a GS1 company prefix belonging to the network operator, a serial number for the connection, and a final check digit.
Length18 digits
Stays with the property when you switch supplier?Yes
Where to find itOn the supplier’s annual statement (jaarafrekening) and energy bills, usually in the block with the connection details; in the customer portal of the network operator (for example Mijn Liander); or by searching the address in the public EAN-codeboek. The code is not printed on the meter itself.
Electronic accessThe EAN-codeboek (eancodeboek.nl) lets anyone look up the EAN codes and network operator for an address by postcode and house number. Suppliers, network operators and other registered market parties exchange connection, switching and meter data through EDSN’s central systems.
Third-party accessLicensed suppliers and registered market parties, such as comparison sites with an official connection, can query connection data. Consumption data from the smart meter can only be shared with third parties with the customer’s consent; the network operator may read the meter without consent only for the annual bill, up to 12 monthly overviews, switching, moving house and grid management.
Who keeps the registerThe central connection register behind the EAN-codeboek, maintained by EDSN on behalf of all network operators. Each operator creates and maintains the records for its own connections.
Register scopeNational

What the EAN code identifies

Every electricity connection (aansluiting) in the Netherlands has a unique EAN code; a home with gas has a second, separate EAN code for the gas connection. The code identifies the connection point, not the meter or the supplier: it stays the same when the supplier changes or the meter is replaced, and it is never reused for another connection. When a household moves, it takes over the EAN code of the new address.

Format

The 18 digits follow the GS1 Global Service Relation Number structure. The leading part is a company prefix issued to the network operator through GS1, followed by the serial number the operator gives to the connection, and a check digit calculated from the other 17 digits so that systems can catch typing errors. In practice households never need to decode it; they quote the full code when switching supplier, registering solar panels or contacting the network operator.

Who holds the register

The network operator creates the EAN code when a new connection is built, usually after a request through the national portal Mijnaansluiting.nl. The record is held in the central connection register managed by EDSN, the network operators’ joint data organisation, which also handles supplier switches and moving-house messages and distributes meter readings. Because this register is national, a supplier can identify and register any connection in the country from one source.

Used for registrations

The EAN code is also the key for registering generation and storage. Owners must register solar panels and, since July 2022, batteries of 0.8 kW or more with their network operator through energieleveren.nl, which links the equipment to the connection’s EAN code.

Sending electricity to the grid.

Sending electricity to the grid.
QuestionAnswer
Can homes export electricity?Yes
Net meteringYes
Net billingNo
How exported electricity is paidUntil 31 December 2026: full net metering (salderingsregeling) against consumption, plus a supplier-set feed-in rate for any annual surplus. From 1 January 2027: a supplier feed-in payment for every kWh exported, which until 2030 must be at least 50% of the supplier’s bare supply price
When does net metering end?The salderingsregeling stops on 1 January 2027. Until 31 December 2026 every kWh fed back can be offset one-to-one against consumption, including energy tax. From 2027 households pay for all electricity taken from the grid and receive a separate payment for what they feed in.
Is there a minimum feed-in payment after 2027?Yes. Until 2030 the supplier’s feed-in payment must be at least 50% of its bare supply price (the electricity price excluding taxes).
Can suppliers charge for feed-in?Yes. Many suppliers charge a fee per kWh fed back. These charges must reflect the supplier’s actual costs, and ACM supervises them. ACM found in 2025 that the charges were not unreasonably high and asked suppliers to express them uniformly per kWh.
Is self-consumed solar power taxed?No. Electricity that a household generates and uses directly is free of energy tax and supplier charges.
What inverter requirements apply?Since 27 April 2021, new installations must use inverters with a conformity certificate showing compliance with the EU Requirements for Generators (type A) through NEN-EN 50549-1.
Do batteries have to be registered?Yes. Since 8 July 2022 the grid code requires storage of 0.8 kW or more connected to the grid to be registered with the network operator via energieleveren.nl. Systems above 1 MW need a separate storage module document before commissioning.
Does grid congestion stop households exporting?Existing household connections can still feed in. Congestion mainly affects new connections and larger connections: from 1 July 2026 small consumers asking for a new or heavier connection in congested areas join the same waiting list as businesses.

Connecting a home system.

  1. Choose an installer; installation must meet NEN 1010 (electrical) and NEN 7250 (building aspects), and the inverter must have an RfG conformity certificate to NEN-EN 50549-1.
  2. Check whether the roof installation is permit-free (it usually is, unless the building is a monument or in a protected townscape) using the Omgevingsloket permit check.
  3. Confirm that the existing connection and meter are suitable; homes with an old meter that cannot record feed-in separately will have it replaced free of charge by the network operator.
  4. Register the panels (and any battery of 0.8 kW or more) with the network operator through energieleveren.nl, using the connection’s EAN code.
  5. Tell the supplier, which applies net metering until the end of 2026 and a feed-in payment (and any feed-in charge) under the contract from 2027.

For more than a decade the Netherlands offered one of the most generous treatments of household solar in Europe: under the salderingsregeling, electricity fed back to the grid was netted against electricity taken from it, so each exported kWh was worth the full retail price including energy tax. This, together with 0% VAT on panels for homes since 2023, explains why more than three million homes have solar panels.

The scheme ends on 1 January 2027. The government argued that it raised prices for households without solar, cost tax revenue and was no longer needed because panels had become cheaper. From 2027 a household with solar will pay energy tax on everything it imports and receive a feed-in payment of at least half the bare supply price until 2030. This makes self-consumption much more valuable and is the main driver of interest in home batteries, smart charging and dynamic contracts.

Physically, connecting rooftop solar does not require prior approval from the network operator for a normal home connection, but it must be registered. Network operators have warned that home batteries trading on national price signals can add to local congestion.

Licensing and approvals.

Requirements depend on the activity. The table sets out what each activity needs and who grants it.

Licensing and approvals.
ActivityLicence or registrationAuthorityNotes
Generate electricityNo generation licence at any size. Generators must have a connection agreement with the network operator, comply with the grid code (RfG type classes from 0.8 kW) and register the installation.Network operator; ACM (grid code)Larger projects need environmental permits under the Omgevingswet and, for offshore wind, a permit from the Ministry of Climate and Green Growth through a tender.
Store electricityNo licence. Storage of 0.8 kW or more must be registered with the network operator via energieleveren.nl; above 1 MW a storage module document (ESMD) is required before commissioning.Network operatorGrid-scale batteries need a connection, which in congested areas may only be available on flexible or time-limited terms.
Export to the gridNo licence for households or businesses. Requires a connection with feed-in capacity and a contract with a supplier or other party that takes the electricity.Network operator; supplierLarge feed-in connections in congested areas are placed on a waiting list.
Supply electricity to small consumersACM supply licence (leveringsvergunning) required to supply end-users with a small connection (up to 3×80 A).ACMUnder the Energiewet ACM can apply a Bibob integrity test to applicants and existing licence holders and tests suppliers’ financial resilience. Licence holders must offer ACM model contracts.
Active customer (generate, store, sell, share own power)No licence, provided these activities are not the customer’s main commercial activity.EnergiewetActive customers are not themselves balance-responsible; that responsibility stays with their supplier or another market party.
Energy communityNo supply licence needed for a non-profit energy community supplying its members.Energiewet; ACMEnergy sharing currently works only where giver and receiver have the same supplier, and suppliers are not obliged to offer it.
Aggregate flexibility or feed-inNo specific licence. Aggregators register as market parties and either act as or contract a balance-responsible party; to offer balancing services they must prequalify with TenneT as a BSP.TenneT; ACMThe Energiewet recognises feed-in aggregation, peer-to-peer trading and demand response as forms of aggregation.
Peer-to-peer tradingNew role under the Energiewet; the facilitator registers as a market party through Partners in Energie and acts as supplier towards the participants.Network operators (registration); ACMAllows households and businesses to trade electricity directly.
Wholesale tradingNo licence for trading itself. Physical traders need a BRP or a contract with one; exchange membership for direct trading.TenneT (BRP recognition); ACM (REMIT)ACM enforces REMIT registration and insider-information rules for wholesale market participants.
Balancing services (FCR, aFRR, mFRR)Prequalification with TenneT as a balancing service provider (BSP). The minimum bid for aFRR is 1 MW, which can be met by aggregating small assets.TenneTIn June 2026 Balans Energie became the first BSP qualified for aFRR using only aggregated home batteries.
Congestion management (grid services)No licence. Contract with the network operator (capacity-limitation contracts) or bid redispatch through GOPACS.Network operators; TenneTAggregators (CSPs) can take part on behalf of several connections.
Remote control of household assetsNo specific licence or registration for controlling home batteries, heat pumps or chargers. The installed equipment must meet the grid code and be registered where required.—Network operators have called for rules on grid-aware use of home batteries before they are encouraged further.

The Netherlands licenses only one activity in the electricity chain that matters for households: supplying small consumers. Generating, storing and exporting electricity need no licence, only a network connection, registration of the installation and compliance with the grid code. This is why households, housing associations and businesses can install solar panels and batteries without dealing with the regulator.

The Energiewet adds roles from the EU Electricity Directive. Active customers may generate, store, sell and share their own electricity without a licence as long as this is not their main business; energy communities can supply their members without a supply licence; and aggregators and peer-to-peer traders have a recognised place in the market. Balance responsibility and TenneT’s prequalification remain the gateways to the wholesale and balancing markets.

Flexibility and grid services.

Aggregation of home equipment: Yes

Flexibility and grid services.
Market or serviceAccess for home equipmentMinimum sizeVia an aggregatorDetail
Automatic frequency restoration reserve (aFRR)Yes1 MWYesTenneT. Main Dutch balancing product. BSPs must respond within 30 seconds of TenneT’s signal. In June 2026 the first BSP using only aggregated home batteries (6 MW, 25 MWh) started delivering aFRR.
Frequency containment reserve (FCR)Yes—YesTenneT. Fast frequency reserve; providers must prequalify with TenneT as a BSP.
Manual frequency restoration reserve (mFRR)Yes—YesTenneT. Slower reserve product, used alongside aFRR; prequalification as BSP required.
Passive balancing (imbalance)Yes—YesTenneT / BRPs. TenneT publishes imbalance prices in near real time, and BRPs and suppliers steer batteries and other flexible assets to help the system balance and avoid imbalance charges.
Congestion management (GOPACS, CSC contracts)Yes—YesTenneT and regional network operators. Grid users and aggregators can sell redispatch bids or sign capacity-limitation contracts (CSC) under which they reduce use at peak times in exchange for a payment or discount.
Wholesale (day-ahead and intraday)Developing—LimitedEPEX SPOT, Nord Pool. Households access wholesale price signals through dynamic contracts, often combined with automated control of a battery, heat pump or EV charger.

Flexibility is a central topic in the Netherlands because grid congestion, rather than generation capacity, has become the main constraint. ACM has introduced new contract forms such as capacity-limitation contracts and group transport agreements, and network operators use GOPACS to buy redispatch. Most of these instruments are aimed at businesses with large connections.

For households, flexibility currently comes mainly through markets rather than the network operator: dynamic contracts, supplier-controlled batteries and aggregators that bundle home batteries for TenneT’s balancing markets. The planned time-dependent network tariff for small consumers, expected in 2029, would add a direct local signal to use the grid at quiet times.

Flexibility and aggregation platforms.

Flexibility and aggregation platforms.
Platform or aggregatorWhat it does
GOPACSJoint congestion-management platform of TenneT, Liander, Enexis, Stedin, Coteq, Rendo and Westland Infra.
Energieleveren.nlNetwork operators’ registration portal for solar panels and batteries connected to small connections.

Smart meters.

Smart meters.
FactValue
Smart-meter rolloutNetwork-operator rollout from 2015; 94% of households had a new meter by January 2026, and the Energiewet now requires the rest to be replaced
Reading interval15 minutes (electricity) for detailed data with consent; up to 12 monthly readings without consent
Households with a new meter94% (January 2026)
Old meters still to replaceAbout 500,000
Smart electricity meters (2023)6.9 million
Who installs and ownsRegional network operator, free of charge
Readings without consentAnnual bill, up to 12 monthly overviews, switching, moving and grid management
Opt-outRemote reading can be switched off; the household then submits readings itself
Local data portP1 port for live readings by home energy managers
Energiewet obligationEvery home must have a smart or digital meter that records import and export separately

Who does what

In the Netherlands smart meters are the network operator’s responsibility, not the supplier’s. Each regional operator installed meters in its own area, starting with a large-scale rollout in 2015 under which all small consumers were offered a free smart meter. The operator owns and maintains the meter, collects and validates the readings, and passes them through the network operators’ shared EDSN systems to the household’s supplier for billing.

Privacy and data

Privacy rules limit remote reading. Without the household’s consent, the network operator may read the meter once a year for the annual bill, up to 12 times a year for monthly overviews, when the household switches supplier or moves, and when needed for grid management. More frequent data, such as daily or quarter-hourly readings used by energy apps or dynamic contracts, needs explicit consent. Households can ask the network operator to switch off remote reading altogether and submit readings themselves. The P1 port on the meter lets households connect their own display, energy manager or battery controller to read live data locally.

Completing the rollout

Because net metering ends in 2027, every meter must be able to measure consumption and feed-in separately. The Energiewet, in force since January 2026, therefore requires all households to have either a smart meter or a digital meter (which records import and export but is not read remotely). Network operators are replacing the last roughly 500,000 old meters free of charge, and the Rijksinspectie Digitale Infrastructuur supervises compliance.

Renewable electricity.

Electricity generation mix (2025).

  • Natural gas: 36.4%
  • Wind (onshore): 12.5%
  • Wind (offshore): 11.9%
  • Solar: 19.7%
  • Coal: 9.1%
  • Biomass: 4.8%
  • Nuclear: 2.9%
  • Oil, other fuels and other sources: 2.8%
Source 5
Renewable electricity share
48.5% (2025)Source 6Derived: renewable gross electricity production of 65,650 GWh (CBS 82610NED) divided by total gross production of 135,365 GWh (CBS 84575NED). CBS expresses renewable output as 54.1% of electricity consumption, because the Netherlands was a net exporter in 2025.
Home solar
3,041,895 homes with solar panels (end 2025)Source 7With 12.09 GWp of panel capacity, about 41% of national solar capacity. Equivalent to roughly 36% of households (derived from 8.475 million households).
Solar added each year
1.45 GWp (2025)Source 7Derived: 29.43 GWp at end 2025 minus 27.98 GWp at end 2024.
Solar PV
29.4 GWp (end 2025)Source 7
Onshore wind
7 GW (end 2025)Source 6
Offshore wind
4.7 GW (end 2025)Source 6
Natural gas plant
17.4 GW (2025)Source 8
Large batteries (>1 MWh)
0.35 GW (end 2024)Source 9

Targets.

  • 21 GW of offshore wind by 2032 under the offshore wind roadmap, with an adjusted ambition of 30–40 GW by 2040.
  • Subsidised permits for 2 GW of offshore wind in 2026, after a subsidy-free tender attracted too little interest.
  • Ban on coal-fired electricity production from 1 January 2030.

Renewables produced 65.7 TWh in 2025, equal to 54.1% of Dutch electricity consumption and about 48.5% of gross generation. Wind supplied 24.4% of net generation, split almost equally between onshore and offshore, and solar 19.7%. Natural gas remains the largest single source at 36.4% and usually sets the wholesale price; coal still supplied 9.1% ahead of the 2030 ban, and the single nuclear plant at Borssele about 3%.

Solar growth has slowed sharply. Installed capacity grew by only about 1.45 GWp in 2025 to 29.4 GWp, as the end of net metering, falling feed-in value and grid congestion weighed on both rooftop and field projects. Offshore wind faces a weaker business case: the government reported in September 2025 that a subsidy-free tender attracted little interest, postponed two 1 GW sites and plans to grant 2 GW of offshore permits with subsidy in 2026.

The Netherlands was a net exporter in 2025, exporting 30.4 TWh and importing 16.3 TWh, mainly to and from Belgium and Germany.

Energy storage.

Home batteries
Not identified from a reliable public source.
Grid-scale storage
0.35 GW (end 2024)Source 984 batteries of more than 1 MWh with 620 MWh of storage, up from 40 systems and 343 MWh a year earlier.

Grid-scale storage in the Netherlands is still small compared with its solar and wind fleet: CBS counted 350 MW and 620 MWh of large batteries at the end of 2024. Many more projects are being developed, often at existing power station sites or alongside solar farms, but they compete for the same scarce grid connections as other users. Batteries that relieve congestion are one of the categories that can receive priority under ACM’s prioritisation framework.

Home batteries are expected to grow as net metering ends, but they do not qualify for the 0% VAT rate that applies to solar panels. Network operators distinguish between batteries that simply store a household’s own solar power, which tend to reduce peaks, and batteries that trade on national price signals, which can add to local congestion, and have asked for clear rules before batteries are actively encouraged.

Storage projects.

  • RWE Moerdijk: 400 MW / 1,100 MWh battery at the Moerdijk power station in North Brabant, with commissioning planned for the second quarter of 2028 (investment decision announced September 2026).
  • Aggregated home batteries in aFRR: Since June 2026 a portfolio of home batteries (initially 6 MW / 25 MWh) has been qualified to deliver aFRR balancing reserve to TenneT.

Electricity suppliers.

Electricity suppliers.
SupplierMarket shareRenewable tariffTime of useDynamicExport tariff
Vattenfall~1.7 million household customers (ACM Energiemonitor, August 2025)YesLimitedYesYes
Essent~1.5 million household customers (ACM Energiemonitor, August 2025)YesLimitedYesYes
Eneco~1.3 million household customers (ACM Energiemonitor, August 2025)YesLimitedYesYes
Budget Energie~750,000 household customers (August 2025)YesLimitedUnknownYes
Greenchoice~600,000 household customers (August 2025)YesLimitedUnknownYes
ANWB Energie~132,000 household customers (August 2025); market leader in dynamic contractsYesLimitedYesYes

The three largest suppliers, Vattenfall, Essent and Eneco, together serve roughly 60% of Dutch households, followed by Budget Energie, Energiedirect, Greenchoice, Engie, Oxxio, Vandebron and ANWB Energie. Customer numbers above come from ACM’s Energiemonitor as of 14 August 2025, as reported by a comparison site; ACM does not publish a supplier-by-supplier table on its own pages.

Dynamic contracts are a fast-growing niche: 32 suppliers offered them at the start of 2025, and ANWB Energie had the largest share. Every supplier must offer feed-in compensation to households with solar panels, and many now add a per-kWh feed-in charge. Smart meters are installed by network operators, not suppliers, so all suppliers can bill on smart-meter readings.

Key organisations.

Key organisations.
OrganisationCategoryWhat it doesWhy it matters
Ministry of Climate and Green Growth (KGG)GovernmentEnergy and climate policyOwns the Energiewet, the end of net metering, offshore wind planning and the national approach to grid congestion.
Netherlands Enterprise Agency (RVO)GovernmentSubsidy and statistics agencyRuns ISDE for heat pumps and insulation, SDE++ for larger renewable projects, and publishes EV and installation-standard information.
Statistics Netherlands (CBS)GovernmentNational statistics officePublishes energy prices, household consumption, solar, wind, heat pump and battery statistics used throughout this profile.
Autoriteit Consument & Markt (ACM)RegulatorEnergy regulator and competition authorityLicenses suppliers, sets network tariffs and codes, and decides how scarce grid capacity is allocated.
TenneTTransmissionTransmission system operatorOperates the national and offshore grid and the balancing markets.
Netbeheer NederlandDistributionAssociation of Dutch network operatorsPublishes the capacity map, queue figures and joint positions on tariffs, meters and home batteries.
LianderDistributionLargest regional network operatorServes North Holland, Gelderland, Flevoland and Friesland.
EnexisDistributionRegional network operatorServes Groningen, Drenthe, Overijssel, North Brabant and Limburg.
StedinDistributionRegional network operatorServes most of South Holland, Utrecht and Zeeland, including Rotterdam and The Hague.
Energie Data Services Nederland (EDSN)MeteringNetwork operators’ data hubMaintains the EAN-codeboek and the systems for switching and meter data exchange.
GOPACSFlexibilityCongestion-management platformWhere grid users and aggregators offer flexibility to TenneT and regional network operators.
Holland SolarSolarSolar industry associationRepresents solar installers and developers in policy and technical discussions.
Energy Storage NLStorageStorage industry associationRepresents battery and other storage developers on grid access and market rules.
Milieu CentraalConsumerIndependent consumer energy informationExplains solar, heat pumps, subsidies and the end of net metering for households.

Technical standards.

Technical standards.
AreaStandardIssued byNotes
Electrical installationNEN 1010NENThe main low-voltage installation standard; network operators require compliance through the grid code. Applies to solar, batteries and chargers.
Building aspects of solar systemsNEN 7250NENTest and calculation methods for meeting building regulations (fire, wind load, water tightness) with solar installations.
Inverters / grid connectionNEN-EN 50549-1 (EU Requirements for Generators, type A)CENELEC / NEN; ACM grid codeInverters for new installations must have a conformity certificate since 27 April 2021. Settings include voltage and frequency protection and anti-islanding.
Grid codeNetcode elektriciteitACMTechnical conditions for connections, including registration of generation and of storage from 0.8 kW.
InspectionSCIOS Scope 12SCIOSCertification scheme for the inspection of solar energy installations.
Installer qualityZon op woningen code of conductSolar industryVoluntary code setting safety and quality requirements before, during and after installation on homes.
Building regulationsBesluit bouwwerken leefomgeving (Bbl)Government (Omgevingswet)Sets permit-free conditions for solar panels and heat pumps, including the 40 dB noise limit for outdoor units next to neighbouring homes.

Permissions.

Permissions.
PermissionRequiredLevelDetail
Permit – rooftop solarLimitedNationalPermit-free if the panels are in the roof plane at the roof’s angle (or set back from the edge on a flat roof by at least their own height), and the building is not a municipal, provincial or national monument. In protected townscapes only on rear roofs not facing public space.
Permit – heat pump outdoor unitLimitedNationalPermit-free if no more than 1 m high and 2 m² in area and compliant with the Bbl; the unit must not exceed 40 dB at an adjoining home.
Network operator notificationYesNationalSolar panels and batteries of 0.8 kW or more must be registered via energieleveren.nl. No prior approval is needed within an existing small connection.
Heavier or new connectionYesRegionalRequested from the network operator through Mijnaansluiting.nl. From 1 July 2026, in congested areas small consumers join the same waiting list as businesses unless they qualify for priority.
Monument permitYesLocalSolar panels on a listed building need an environmental permit from the municipality.

For a normal home, rooftop solar and most heat pumps can be installed without a permit under national rules in the Besluit bouwwerken leefomgeving, and the Omgevingsloket offers an online permit check. Monuments and protected townscapes are the main exceptions.

The bigger hurdle is now grid capacity. Since 1 July 2026 network operators no longer automatically reserve capacity for small consumers, so a household that needs a new or heavier connection, for example for a heat pump, induction hob or EV charger, can end up on a waiting list in congested areas. In 2025 the average wait for a new connection was about 45 weeks and for an upgrade about 21 weeks.

Support schemes, taxes and incentives.

Support schemes, taxes and incentives.
SchemeStatusTypeDetailPeriod
Salderingsregeling (net metering)ActiveNet meteringElectricity fed back is netted one-to-one against consumption, including energy tax. Ends on 1 January 2027.until 31 December 2026
Minimum feed-in compensationScheduledExport paymentAfter net metering ends, suppliers must pay at least 50% of their bare supply price for electricity fed back, until 2030.1 January 2027 – 2030
0% VAT on residential solar panelsActiveVAT reliefSupply and installation of solar panels on or at a home are zero-rated. Does not apply to home batteries, which carry 21% VAT, or to integrated panels on new-build homes.since 1 January 2023
ISDE (Investeringssubsidie duurzame energie)ActiveGrantGrants for homeowners for heat pumps, solar water heaters, insulation, electric cooking and heat network connections. In 2026 a first air-to-water heat pump receives €1,025 plus €225 per kW and a €200 energy-label bonus; split units with less than 3 kg of high-GWP refrigerant are excluded.2026 round opened 5 January 2026
Energy tax credit (vermindering energiebelasting)ActiveTax creditFixed annual reduction of €519.80 before VAT (€628.96 with VAT) per household connection in 2026.2026
Prijsplafond (energy price cap)ClosedPrice capTemporary cap on household electricity prices for consumption up to a set annual volume during the 2022–23 energy crisis.2023

Data and connectivity.

Fixed broadband
98.4 % of households with gigabit-capable (VHCN) coverage (2024)Source 41Fibre-to-the-premises coverage was 85.3%.
4G coverage
Not identified from a reliable public source.
5G coverage
100 % of populated areas, overall 5G coverage (2024)Source 41

The Netherlands has near-universal gigabit broadband and full 5G coverage, so connectivity is rarely a barrier to smart energy devices. Smart meters are read remotely by the network operator; this does not depend on the household’s own internet connection.

Inside the home, energy managers, batteries and EV chargers typically read live data from the smart meter’s P1 port and connect to manufacturers’ or suppliers’ cloud platforms over Wi-Fi. Suppliers with dynamic contracts and aggregators control devices through these cloud connections.

Grid conditions.

National peak demand
Not identified from a reliable public source.
Annual electricity demand
112.8 TWh (2025)Source 5CBS calculated net consumption, after distribution losses of 4.7 TWh.
Generation capacity
62.7 GW (2025)Source 8Installed electrical capacity including 25.9 GW of solar (CBS method) and 11.8 GW of wind.
Interconnection
Not identified from a reliable public source.
Curtailment
Not identified from a reliable public source.

Grid congestion

Netcongestie is the defining issue of the Dutch power system. Demand from industry, housing and electrification, together with large amounts of solar, has outgrown network capacity in many regions. In October 2025 regional network operators had 14,044 requests for consumption capacity (9.1 GW) and 8,539 requests for feed-in capacity (4.6 GW) waiting, and TenneT’s own queue held 212 consumption requests (38 GW) and 161 feed-in requests (34 GW).

ACM’s prioritisation framework gives precedence to projects that relieve congestion (such as batteries), to safety-critical users and to basic needs such as housing, schools and public transport. Since 1 July 2026 small consumers no longer have automatic reserved capacity and join the same queue in congested areas, with a transition period until 1 January 2027.

Responses

Network operators are expanding and reinforcing the grid, and ACM has introduced flexible contract forms, group transport agreements and time-dependent network tariffs for large users, with time-dependent tariffs for small consumers proposed for 2029. ACM is also advising the ministry on a possible capacity mechanism for security of supply as gas and coal plants close.

Grid and capacity maps.

Regulatory changes.

Regulatory changes.
ChangeStatusDateDetail
Energiewet in forceCurrent1 January 2026Replaces the Electricity Act 1998 and Gas Act. Introduces active customers, energy communities, peer-to-peer trading and energy sharing, mandatory fixed and variable model contracts, stronger ACM powers over suppliers and the obligation for every home to have a smart or digital meter.
End of net metering (salderingsregeling)Upcoming1 January 2027Feed-in will no longer be netted against consumption. Suppliers must pay at least 50% of the bare supply price for exported electricity until 2030, and feed-in charges must be cost-reflective.
Small consumers join the grid waiting listCurrent1 July 2026 (transition to 1 January 2027)Network operators stopped reserving capacity for small connections. In congested areas new and heavier household connections now go on the same waiting list as businesses, ranked by ACM’s prioritisation framework.
Time-dependent network tariffs for householdsUpcomingExpected 2029Network operators proposed in May 2026 that two-thirds of the transport tariff for connections up to 3×80 A become volume- and time-dependent. ACM expects a draft decision around summer 2026 and introduction in 2029.
Time-dependent network tariffs for large consumersUpcomingDecision expected end 2026ACM plans to adopt a time-dependent tariff structure for large connections on regional networks by the end of 2026.
Offshore wind subsidies returnUpcoming2026After weak interest in subsidy-free tenders, the government plans to permit 2 GW of offshore wind with subsidy in 2026, keeping the 21 GW by 2032 roadmap and a 30–40 GW ambition for 2040.
Coal ban for power generationUpcoming1 January 2030Use of coal for electricity production will be prohibited, removing the remaining coal plants (3.4 GW in 2025).

Market indicators.

Neutral descriptions of the market, each with the evidence behind it. They do not rank countries.

Market indicators.
IndicatorLevelBasis
Electricity costMediumLow below €0.15 per kWh, high at €0.30 or more (household price including taxes, converted to euros).
Household electricity useMediumLow below 2,500 kWh a year, high at 5,000 kWh or more (average use per household).
Renewable shareMediumLow below 30%, high at 60% or more (renewable share of electricity).
Smart-meter adoptionHighLow below 30%, high at 80% or more (share of meters that are smart).
Home solar adoptionHigh3.04 million homes (about 36% of households) had solar panels at the end of 2025, with 12.1 GWp of capacity (CBS).
Distributed energy marketHigh29.4 GWp solar, about 830,000 hydronic heat pumps plus 1.74 million air-to-air units in homes, and 770,000 battery-electric cars (August 2026).
Grid flexibility marketMediumAggregation allowed in aFRR (1 MW minimum), passive balancing and GOPACS congestion management; first home-battery aFRR portfolio qualified in June 2026; household time-dependent network tariffs not before 2029.
Energy storage adoptionLow350 MW / 620 MWh of large batteries at end 2024 (CBS); no reliable count of home batteries; several large projects in development.
Renewable growth environmentHighRenewables equal to 54.1% of consumption and about 48.5% of gross generation in 2025, though solar additions slowed to 1.45 GWp in 2025.

Sources.

Public sources used for this profile, with the date each was accessed.

Show all 41 sources
  1. Gemiddelde energietarieven voor consumenten (85592NED). CBS, 2026. accessed 1 October 2026.
  2. Bevolking; kerncijfers (85496NED). CBS, 2026. accessed 1 October 2026.
  3. Energieverbruik particuliere woningen; woningtype en regio's (81528NED). CBS, 2026. accessed 1 October 2026.
  4. Woningvoorraad; kenmerken woning en bewoning op 31 december, regio (86079NED). CBS, 2026. accessed 1 October 2026.
  5. Elektriciteitsbalans; aanbod en verbruik (84575NED). CBS, 2026. accessed 1 October 2026.
  6. Hernieuwbare elektriciteit; productie en vermogen (82610NED). CBS, 2026. accessed 1 October 2026.
  7. Zonnestroom; vermogen en vermogensklasse, bedrijven en woningen, regio (85005NED). CBS, 2026. accessed 1 October 2026.
  8. Elektriciteit en warmte; productie, inzet en vermogen naar energiedrager (86266NED). CBS, 2026. accessed 1 October 2026.
  9. Grote batterijen voor opslag van elektriciteit (85929NED). CBS, 2025. accessed 1 October 2026.
  10. Warmtepompen; aantallen, thermisch vermogen en energiestromen (85523NED). CBS, 2026. accessed 1 October 2026.
  11. Verbeterd inzicht in energieverbruik van woningen met slimme-metergegevens – slimme-metergegevens van kleinverbruiksaansluitingen. CBS, 2025. accessed 1 October 2026.
  12. Elektrisch vervoer – stand van zaken. RVO, 2026. accessed 1 October 2026.
  13. Urban population (% of total population) – Netherlands. World Bank, 2025. accessed 1 October 2026.
  14. Electric power consumption (kWh per capita) – Netherlands. World Bank, 2024. accessed 1 October 2026.
  15. Salderingsregeling. Rijksoverheid, 2026. accessed 1 October 2026.
  16. FAQ Energiewet. Netbeheer Nederland, 2025. accessed 1 October 2026.
  17. Actief deelnemen aan de energietransitie onder de Energiewet. Omgevingsweb, 2026. accessed 1 October 2026.
  18. Nieuwe Energiewet vereist vervangen oudere meters. Netbeheer Nederland, 2026. accessed 1 October 2026.
  19. Slimme meter en privacy. Rijksoverheid. accessed 1 October 2026.
  20. EAN-code: wat is het en waar vind je hem?. Keuze.nl. accessed 1 October 2026.
  21. EAN-code. Energievergelijk.nl. accessed 1 October 2026.
  22. GSRN for electrical installations. GS1 Sweden. accessed 1 October 2026.
  23. Wachtlijsten groeien, meer inzet op flexibel gebruik essentieel. Netbeheer Nederland, 2025. accessed 1 October 2026.
  24. Wachtlijst voor stroom: dit verandert er per 1 juli voor huishoudens. BNNVARA Kassa, 2026. accessed 1 October 2026.
  25. Voorstel codewijziging volume- en tijdsafhankelijke transporttarieven voor kleinverbruikers. ACM, 2026. accessed 1 October 2026.
  26. Focus op Energie 2026. ACM, 2026. accessed 1 October 2026.
  27. ISDE: wat is er gewijzigd vanaf 2026?. RVO, 2026. accessed 1 October 2026.
  28. Btw-tarief zonnepanelen. Belastingdienst. accessed 1 October 2026.
  29. Installatienormen zonne-energie. RVO. accessed 1 October 2026.
  30. Conformiteitscertificaat omvormers zonnepanelen per 27 april 2021 definitief verplicht. Solar Magazine, 2021. accessed 1 October 2026.
  31. Consumenten en bedrijven moeten batterij verplicht registreren bij netbeheerder. Solar Magazine, 2022. accessed 1 October 2026.
  32. Thuisbatterijen: spelregels nodig voor netbewust gebruik. Netbeheer Nederland, 2024. accessed 1 October 2026.
  33. Zonnepanelen: voorwaarden vergunningvrij plaatsen. IPLO. accessed 1 October 2026.
  34. Plaatsen van een warmtepomp. IPLO. accessed 1 October 2026.
  35. Kamerbrief Structuurvisie Windenergie op Zee (Kamerstuk 33561, nr. 91), 16 September 2025. Ministerie van Klimaat en Groene Groei, 2025. accessed 1 October 2026.
  36. Thuisbatterijen Balans Energie starten met balanceren stroomnet. Solar Magazine, 2026. accessed 1 October 2026.
  37. RWE bouwt een van de grootste Nederlandse batterijopslagsystemen. IO+, 2026. accessed 1 October 2026.
  38. Dit is de top 10 grootste energieleveranciers (ACM Energiemonitor, 14 August 2025). Keuze.nl, 2025. accessed 1 October 2026.
  39. 423.000 consumenten hebben een dynamisch energiecontract voor stroom. Solar Magazine, 2025. accessed 1 October 2026.
  40. GOPACS – congestion management. GOPACS. accessed 1 October 2026.
  41. Digital Decade 2025 country report – the Netherlands (Council document 10407/25 ADD 21). European Commission, 2025. accessed 1 October 2026.